北京市托幼单位消毒工作现状调查
引用本文:曹国华,邓小虹.北京市托幼单位消毒工作现状调查[J].中国消毒学杂志,1997,14(3):174-176.
作者姓名:曹国华  邓小虹
作者单位:北京市卫生防疫站
摘    要:1993~1995年,经细菌检测,北京托幼单位在全年中以第三季度物体表面与室内空气卫生合格率较低,分别为70.29%与70.93%。应用中消毒液合格率(70.83%)亦较低。物体表面卫生合格率,市区、近郊区与远郊县分别为84.25%、83.24%与80.90%,手卫生合格率分别为80.09%、78.16%与76.99%。

关 键 词:污染调查  托幼单位消毒  物体表面  室内空气    消毒液

SURVEY OF PRESENT STAUTS OF DISINFECTION WORK IN NURSERIES AND KINDERGARTENS IN BEIJING
Cao Guohua,Deng Xiaohong.SURVEY OF PRESENT STAUTS OF DISINFECTION WORK IN NURSERIES AND KINDERGARTENS IN BEIJING[J].Chinese Journal of Disinfection,1997,14(3):174-176.
Authors:Cao Guohua  Deng Xiaohong
Institution:Cao Guohua,Deng Xiaohong. Beijing Municipal Sanitary and Anti-epidemic Station,Beijing 100013
Abstract:It was found in a survey (1993~1995) that the hygienic eligible rate of surfaces of articles and indoor air in nurseries and kindergartens in Beijing was low in third quarter of a year, being 70.29% and 70.93% respectively. The rate of exceeding allowable limit of contamination of disinfectant solution in use was high. The hygienic eligible rates of surfaces of articles in urban district, near suburban district and far suburban district were 84.25%, 83.24%, 80.90% respectively, and that of hands were 80.09%, 78.16%, 76.99 respectively.
Keywords:survey of contamination    disinfection in nurseries and kindergartens    surface of article  indoor air    hand    disinfectant solution  