首页 | 本学科首页   官方微博 | 高级检索  
     

人工鼻替代加热湿化系统在呼吸机治疗中的应用
引用本文:吕晓玲,夏秋江,罗群,牟宗娟,谭亚男,江高燕,周艳,龚婷婷,李源. 人工鼻替代加热湿化系统在呼吸机治疗中的应用[J]. 中国实用护理杂志, 2009, 25(20). DOI: 10.3760/cma.j.issn.1672-7088.2009.07.043
作者姓名:吕晓玲  夏秋江  罗群  牟宗娟  谭亚男  江高燕  周艳  龚婷婷  李源
作者单位:三峡大学人民医院湖北省宜昌市第一人民医院ICU,443000
基金项目:湖北省卫生厅指导性科研项目 
摘    要:目的 研究人工鼻(HME)替代加热湿化装置在呼吸机治疗中的可行性.方法 将近3年入住ICU的应用呼吸机治疗2 d以上的患者266例,应用阶段性病例分组对照的方法 分为实验组(人工鼻组)141例和对照组(加热湿化器组)125例,在湿化效果、应用人工气道时间、应用呼吸机时间、住ICU的时间、VAP发生率、病死率等方面进行对比研究和分析.结果实验组患者痰液湿化效果好的病例多于对照组,湿化不足、湿化过度及气道痉挛的病例均少于对照组.实验组在应用呼吸机时间和住ICU的时间上均少于对照组.实验组VAP发生率低于对照组.应用人工气道时间2组病例比较无差异;病死率2组病例比较无差异;实验组无湿化意外出现,对照组发生气道烫伤1例,发生呛水11例.结论 在呼吸机治疗中HME可以完全替代加热湿化系统在临床推广应用,但在应用时要注意观察患者病情变化、监测湿化效果和保持人工鼻通畅.

关 键 词:人工鼻  替代  加热湿化器  机械通气

Research in the replacement of heated humidifiers with heat moisture exchangers during mechanical ventilation
LV Xiao-ling,XIA Qiu-jiang,LUO Qun,MU Zong-jun,TAN Ya-nan,JIANG Gao-yan,ZHOU Yan,GONG Ting-ting,LI Yuan. Research in the replacement of heated humidifiers with heat moisture exchangers during mechanical ventilation[J]. Chinese Journal of Practical Nursing, 2009, 25(20). DOI: 10.3760/cma.j.issn.1672-7088.2009.07.043
Authors:LV Xiao-ling  XIA Qiu-jiang  LUO Qun  MU Zong-jun  TAN Ya-nan  JIANG Gao-yan  ZHOU Yan  GONG Ting-ting  LI Yuan
Abstract:Objective To study the feasibility of using heat and moisture exchangers (HME)as an alternative to heated humidifiers (HH) in patients undergoing mechanical ventilation. Methods 266 pa-tients with mechanical ventilation admitted to our ICU over the recent 3 years were allocated to the experi-mental group (humidification with a heat and moisture exchanger) and the control group (with heated hu-midifier), and the effect of humidification, the reserved time of artificial airway, the time on mechanical yen-tilation, the time of stay in ICU, the ineidenee of ventilator-associated pneumonia (VAP) and the mor-tality rate were comparatively studied and analyzed. Results Significant differences were found between the experimental and the control group in effect of humidification, insufficiency of humidification or excessive hu-midification, airway spasm and time on mechanical ventilation and time of stay in ICU. The incidence of VAP in the control group was significantly higher than that in the experimental group. There were no significant dif-ference between the two groups in the reserved time of artificial airway and the mortality rate. There were no accident of humidification occurred in the experimental group while there were one case complicated with air-way burn and 11 eases complicated with choking with water in the control group. Conclusions We conclude that HH can be replaced by HME on mechanical ventilation while disease evolution and effect of humidification should be monitored closely and keep HME unobstructed.
Keywords:Heat and moisture exchanger  Replacement  Heated humidifier  Mechanical venti-lation