首页 | 本学科首页   官方微博 | 高级检索  
检索        


The reliability in determining the deep fascia displacement of the upper trapezius during cervical movement: A pilot study
Institution:1. Department of Physiotherapy, School of Paramedical Sciences, Mashhad University of Medical Sciences, Vakilabad Blvd, Bahonar Blvd, Pardis Campus, Mashhad, Iran;2. Orthopedic Research Center, Shahid Kamyab Hospital, Mashhad University of Medical Sciences, Mashhad, Iran;1. Federal University of Triangulo Mineiro, Uberaba, MG, Brazil;2. Department of Applied Physiotherapy, Federal University of Triangulo Mineiro, Uberaba, MG, Brazil;1. Laboratory of Physiotherapeutic Resources, Postgraduate Program in Rehabilitation and Functional Performance, University of São Paulo, Ribeirão Preto, SP, Brazil;2. Department of Biomechanics, Medicine and Rehabilitation, Ribeirão Preto Medical School, University of São Paulo (USP), Ribeirão Preto, SP, Brazil;3. Department of Clinical Medicine, Medical School of Ribeirão Preto, University of São Paulo, Ribeirão Preto, SP, Brazil;1. Rehabilitation Sciences Post-Graduation Program, Augusto Motta University Centre (UNISUAM), Rio de Janeiro, Brazil;2. Department of Medical Imaging, Allergology and Physiotherapy, Faculty of Dental Medicine, Medical University of Plovdiv, Bulgaria;3. Department of Kinesiotherapy, Faculty of Public Health, Medical University of Sofia, Bulgaria;4. Department of Physical Therapy, School of Medicine, Federal University of Rio de Janeiro (UFRJ), Rio de Janeiro, Brazil;5. Postgraduate Program in Medical Sciences, School of Medical Sciences, State University of Rio de Janeiro (UERJ), Rio de Janeiro, Brazil;1. Bern University of Applied Sciences, Department of Health Professions, Bern, Switzerland;2. Swiss Specialist Group for Analytical Biomachenaics According to Sohier, Switzerland;3. Regional Hospital Baselland-Bruderholz, Institute for Radiology and Nuclear Medicine, Switzerland
Abstract:BackgroundRestricted shoulder fascia displacement may be an etiological factor for myofascial pain syndrome. A diagnostic ultrasound video can follow deep fascia displacement during active cervical movements. Trackers can be applied to videos to convert deep fascia displacement into data points. This study reports on assessors' reliability in evaluating direction and quantifying upper trapezius' deep fascia displacement during active cervical movements.MethodsPT-Sonographer 1 recorded deep fascia displacement of upper trapezius for three sets using HS1 Konica Minolta diagnostic ultrasound. The recording sequence used was cervical flexion, extension, right lateral flexion, left lateral flexion, right rotation, and left rotation. The three assessors used the tracker to determine direction of deep fascia displacement. PT-Sonographer 1 used the tracker three times in quantifying deep fascia displacement. Intraclass correlation coefficient and Kappa determined the assessors' intra-tester and inter-tester reliability.ResultsTen participants were included in the study with a mean±(SD) age of 37±(6). All the assessors had acceptable intra-tester reliability in determining deep fascia displacement on tracker (ICC≥0.40). All assessors had clinically unacceptable inter-tester reliability in determining deep fascia displacement when tracking right rotation (ICC < 0.40). PT-Sonographer 1 had clinically unacceptable intra-tester reliability in determining deep fascia displacement when tracking left rotation (ICC<0.40).ConclusionWe report clinically acceptable assessors' reliability in determining direction and total deep fascia displacement when tracking diagnostic ultrasound videos of cervical flexion, extension, and lateral flexion. Checking for reliable deep fascia displacements may distinguish MPS from non-MPS individuals increasing the utility of diagnostic ultrasound machine and tracker in clinical practice.
Keywords:Fascia  Reproducibility of results  Myofascial pain syndromes  Pain
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号