Toward Accurate Clinical Spasticity Assessment: Validation of Movement Speed and Joint Angle Assessments Using Smartphones and Camera Tracking |
| |
Authors: | Megan Banky Ross A. Clark Benjamin F. Mentiplay John H. Olver Michelle B. Kahn Gavin Williams |
| |
Affiliation: | 1. Department of Physiotherapy, Epworth HealthCare, Melbourne, Australia;2. School of Health and Sport Sciences, University of the Sunshine Coast, Queensland, Australia;3. La Trobe Sport and Exercise Medicine Research Centre, La Trobe University, Melbourne, Australia;4. Victorian Infant Brain Studies, Murdoch Children’s Research Institute, Melbourne, Australia;5. Epworth Monash Rehabilitation Medicine Unit, Melbourne, Australia;6. Department of Physiotherapy, University of Melbourne, Melbourne, Australia |
| |
Abstract: | ObjectiveTo investigate whether a three-dimensional (3-D) camera (Microsoft Kinect) and a smartphone can be used to accurately quantify the joint angular velocity and range of motion (ROM) compared to a criterion-standard 3-D motion analysis system during a lower limb spasticity assessment.DesignObservational, criterion-standard comparison study.SettingLarge rehabilitation center.ParticipantsA convenience sample of 35 controls, 35 patients with a neurologic condition, and 34 rehabilitation professionals (physiotherapists and rehabilitation doctors) participated (N=104).InterventionsNot applicable.Main Outcome MeasuresThe Modified Tardieu Scale was used to assess spasticity of the quadriceps, hamstrings, soleus, and gastrocnemius. Data for each trial were collected concurrently using the criterion-standard Optitrack 3-D motion analysis (3DMA) system, Microsoft Kinect, and a smartphone. Each healthy control participant was assessed by 1 health professional and each patient with a neurological condition was assessed by 3 health professionals. Spearman correlation coefficient and intraclass correlation coefficient with 95% confidence intervals were used to report the strength of the relationships investigated.ResultsThe smartphone and Microsoft Kinect demonstrated excellent concurrent validity with the 3DMA system. Overall, 74.8% of the relationships investigated demonstrated a very strong (≥0.80) correlation across all of the testing parameters. The Microsoft Kinect was superior to the smartphone for measuring joint start and end angle, the smartphone was superior for measuring joint angular velocity, and the 2 systems were comparable for measuring total joint ROM.ConclusionsThese findings provide preliminary evidence that user-friendly, low-cost technologies can be used to facilitate accurate measurements of joint angular velocity and angles during a lower limb spasticity assessment in a clinical setting. |
| |
Keywords: | Corresponding author Megan Banky, BPT, Physiotherapy Department, Epworth Rehabilitation, 29 Erin Street, Richmond VIC 3121, Australia. Muscle spasticity Outcome assessment (health care) Rehabilitation Technology 3-D three-dimensional 3DMA three-dimensional motion analysis ICC intraclass correlation coefficient MTS Modified Tardieu Scale ROM range of motion V1 slow joint movement V3 fast joint movement |
本文献已被 ScienceDirect 等数据库收录! |
|