超声引导Amplatzer封堵器关闭房间隔缺损的初步体会
引用本文:温朝阳,李越,王廉一,王广义,陈练,王禹.超声引导Amplatzer封堵器关闭房间隔缺损的初步体会[J].中华超声影像学杂志,1999,8(5):283-285.
作者姓名:温朝阳  李越  王廉一  王广义  陈练  王禹
作者单位:1. 解放军总医院超声科,北京,100853
2. 解放军总医院心内科,北京,100853
摘    要:目的 超声引导Am platzer封堵器经导管关闭房间隔缺损(ASD)。方法 19例待外科手术Ⅱ孔ASD患者,16例经食道彩色多普勒超声心动图(TEE)、3例经胸彩色多普勒超声心动图(TTE)检查符合条件而行经导管ASD封堵术。在TEE引导(3例TTE)下,以ASD最大伸展径或加1~2 m m 为标准,选择Amplatzer封堵器型号,导管送封堵器到ASD处,依次释放其左房伞、腰部和右房伞,腰部卡于ASD口处,两伞贴于房间隔两侧。结果 3例患者ASD最大伸展径> 34 mm ,没有相应大的封堵器而放弃封堵术,其余16例成功地进行了ASD封堵。超声测量的ASD径[(18.06±7.00)mm ]小于ASD最大伸展径[(22.56±6.25)m m ],差异有显著性(P< 0.01)。术后立即、24 h、1个月、3个月行TTE检查,16例患者封堵器位置合适、稳定,均无残余分流。所有患者术中及术后均无并发症。结论 用Am platzerASD封堵器经导管关闭ASD,超声在病例选择、引导封堵器置入及术后疗效观察等方面有极重要的作用。

关 键 词:超声心动描记术  房间隔缺损  封堵器  Amplatzer

Echocardiographic guidance of transcatheter closure of atrial septal defect
WEN Chaoyang,LI Yue,WANG Lianyi,et al..Echocardiographic guidance of transcatheter closure of atrial septal defect[J].Chinese Journal of Ultrasonography,1999,8(5):283-285.
Authors:WEN Chaoyang  LI Yue  WANG Lianyi  
Institution:WEN Chaoyang,LI Yue,WANG Lianyi,et al. Department of Diagnostic Ultrasound General Hospital of PLA,beijing 100853
Abstract:Objective This study reports our experience of echocardiographic guidance with transcatheter closure of atrial septal defects(ASD)in patients,using the Amplatzer,a new occlusion device.Methods Nineteen patients with secundum ASD waiting for surgical treatment met transesophageal echocardiography(TEE)3 transthoracic echocardiography(TTE)]for transcatheter closure.The Amplatzer size was chosen to be equal to or 1~2mm more than the stretched diameter of ASD.Under uhrasound guidance,The device was advanced to ASD with guiding sheath,and then its left disk,waist and right disk was deployed in turn,Once its position was optimal,it was released.Results Sixteen patients were treated successfully except 3 patients with:>34mm stretched diameters,which were too large for the Amplatzers.The mean ASD diameter by echcardiography was significantly smaller than the mean stretched diameter of the ASD(18.06±7.00)mm vs(22.56±6.25)mm].The devices'positions were optimal and no residual shunt was found by TTE immediately,24 h,1 month and 3 months after the procedure.NO complication was observed during the 3 months fellow up. Conclusions Echocardiography was very important in the selectign of patient,the guidance of the device deployed and the follow-up in the transcatheter closure of ASD with the Amplatzer.
Keywords:Conclusions  Echocardiography was very important in the selection of patient  the guidance of the device deployed and the follow  up in the transcatheter closure of ASD with the Amplatzer      Key words    Echocardiography  Heart septal defe  