Myocardial elastography at both high temporal and spatial resolution for the detection of infarcts
Authors:Luo Jianwen  Fujikura Kana  Homma Shunichi  Konofagou Elisa E
Institution:Department of Biomedical Engineering, Columbia University, New York, NY 10027, USA.
Abstract:Myocardial elastography is a novel method for noninvasively assessing regional myocardial function, with the advantages of high spatial and temporal resolution and high signal-to-noise ratio (SNR). In this paper, in-vivo experiments were performed in anesthetized normal and infarcted mice (one day after left anterior descending coronary artery LAD] ligation) using a high-resolution (30 MHz) ultrasound system (Vevo 770, VisualSonics Inc., Toronto, ON, Canada). Radiofrequency (RF) signals of the left ventricle (LV) in longitudinal (long-axis) view and the associated electrocardiogram (ECG) were simultaneously acquired. Using a retrospective ECG gating technique, 2-D full field-of-view RF frames were acquired at an extremely high frame rate (8 kHz) that resulted in high-quality incremental displacement and strain estimation of the myocardium. The incremental results were further accumulated to obtain the cumulative displacements and strains. Two-dimensional and M-mode displacement images and strain images (elastograms), as well as displacement and strain profiles as a function of time, were compared between normal and infarcted mice. Incremental results clearly depicted cardiac events including LV contraction, LV relaxation and isovolumetric phases in both normal and infarcted mice, and also evidently indicated reduced motion and deformation in the infarcted myocardium. The elastograms indicated that the infarcted regions underwent thinning during systole rather than thickening, as in the normal case. The cumulative elastograms were found to have higher elastographic SNR (SNR(e)) than the incremental elastograms (e.g., 10.6 vs. 4.7 in a normal myocardium, and 6.0 vs. 2.4 in an infarcted myocardium). Finally, preliminary statistical results from nine normal (m = 9) and seven infarcted (n = 7) mice indicated the capability of the cumulative strain in differentiating infracted from normal myocardia. In conclusion, myocardial elastography could provide regional strain information at simultaneously high temporal (>/=0.125 ms) and spatial ( approximately 55 microm) resolution as well as high precision ( approximately 0.05 microm displacement). This technique was thus capable of accurately characterizing normal myocardial function throughout an entire cardiac cycle, at the same high resolution, and detecting and localizing myocardial infarction in vivo.
Keywords:Cardiac  Contraction  Contractility  Deformation  Displacement  ECG gating  Elastogram  Elastography  Heart  High frequency  High resolution  Infarction  Mice  Motion  Myocardium  Strain  Stretching  Systole  Tethering  Thickening  Thinning  Ultrasound
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号