首页 | 本学科首页   官方微博 | 高级检索  
检索        

腰椎峡部裂机翼型记忆合金固定装置的有限元分析
引用本文:朱立新,王健,曹延林,樊望驹,于郭吉,张西兵,叶文明.腰椎峡部裂机翼型记忆合金固定装置的有限元分析[J].中国临床解剖学杂志,2012,30(3):333-336.
作者姓名:朱立新  王健  曹延林  樊望驹  于郭吉  张西兵  叶文明
作者单位:1.南方医科大学附属珠江医院骨科中心, 广州 510282; 2.天津大学化工学院, 天津 300072
摘    要:目的 以正常人体CT影像数据为基础,建立腰椎峡部裂弹性固定有限元模型,分析内固定器受力并对其进行改进。 方法 采用分辨率0.625 mm薄层CT扫描数据,导入 Mimics10.0软件建立三维几何面网格模型,通过Geomagic studio12.0、HyperMesh 10.0前处理,最终导入Abaqus10.1软件生成腰椎峡部裂记忆合金固定模型,并在椎体上表面施加500N压力和7.5 Nm力矩,模拟前屈、后伸、侧屈和旋转四种生理载荷,观察并比较不同载荷下固定装置的应力分布。 结果 机翼型记忆合金固定装置应力集中于侧翼,尤其是侧翼和底座的接合部位,后伸和旋转时最大,容易导致疲劳性断裂。 结论 提高镍钛合金材料质量和工艺水准,术后延长腰围保护时间,以避免机翼型记忆合金固定装置断裂的风险。

关 键 词:腰骶椎  峡部裂  固定装置  有限元分析  
收稿时间:2011-10-27

The finite element analysis of Aerofoil shape memory alloy fixation instrument for surgically treating spondylolysis
ZHU Li-xin , WANG Jian , CAO Yan-lin , FAN Wang-ju , YU Guo-ji , ZHANG Xi-bing , YE Wen-ming.The finite element analysis of Aerofoil shape memory alloy fixation instrument for surgically treating spondylolysis[J].Chinese Journal of Clinical Anatomy,2012,30(3):333-336.
Authors:ZHU Li-xin  WANG Jian  CAO Yan-lin  FAN Wang-ju  YU Guo-ji  ZHANG Xi-bing  YE Wen-ming
Institution:1.Department of Orthopedics, Zhujiang Hospital, Southern Medical University,Guangzhou 510282, China;2.School of Chemical Engineering and Technology,Tianjin University, Tianjin 300072, China
Abstract:Objective To establish the three-dimensional finite element model(FEM) with the bilateral pars defect and reconstruct by AEROFOIL fixation.Methods According to spiral CT scan images of 0.625 mm thickness,finite element model of lumbosacral vertebrae was established using Mimics10.01,Geomagic studio12.0,HyperMesh 10.0 and Abaqus10.1 software.Moreover,it’s validity had been verified and then imported the AEROFOIL fixation.The reconstructed model was analyzed under 500N pressure loading on the upper surface of L1,and 7.5Nm torque loading for simulating axial compression and flexion,extension,lateral bending and rotation.The Von mises stress of fixation were recorded and analyzed.Results It showed that high stress concentrated at the bottom part of the swings,especially at the junction of the swings and the U-shape base.Extension and axial rotation motion resulted in breakage of the AEROFOIL fixation.Conclusions Improving Nitinol material quality and process standards and suitably prolonging the need for external bracing are necessary for reducing the higher risk of fracture on fixation devices.
Keywords:Lumbosacral spine  Spondylolysis  Fixation devices  Finite element analysis
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《中国临床解剖学杂志》浏览原始摘要信息
点击此处可从《中国临床解剖学杂志》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏