首页 | 本学科首页   官方微博 | 高级检索  
检索        

下胸椎前路单钉棒固定系统有限元分析
引用本文:李筱贺,由博,李少华,李志军,王星,陈海芳,张业辉,徐达传.下胸椎前路单钉棒固定系统有限元分析[J].中国临床解剖学杂志,2010,28(2):214.
作者姓名:李筱贺  由博  李少华  李志军  王星  陈海芳  张业辉  徐达传
作者单位:1.南方医科大学临床解剖学研究所, 广州 510515; 2.内蒙古医学院基础医学院解剖学教研室, 呼和浩特 010059;
3.新疆大学机械工程学院, 乌鲁木齐 830003; 4.广东医学院解剖学教研室, 广东 东莞 523808
基金项目:广东省科技计划项目,国家自然科学基金,内蒙古自治区自然科学基金 
摘    要:目的建立T11~12前路病灶清除植骨+单钉单棒固定系统三维有限元模型,分析单钉单棒所受应力对其进行改进。方法对一名成年男性进行螺旋CT扫描,将所得数据导入计算机,通过Mimics13.0软件和Ansys11.0有限元软件建立T11~12前路病灶清除植骨+单钉单棒固定系统三维有限元模型,并在在椎体上表面施加500N压力和10Nm的力矩模拟腰椎前屈、后伸、侧屈和旋转四种生理载荷,观察不同载荷下固定器械的应力分布,并对其进行比较。结果下位椎体钉尾部与连接棒下段为应力较集中部位,两部位在侧弯时最小,旋转时最大,旋转运动容易导致这两部位疲劳性断裂。结论侧前方单钉棒固定系统应增粗螺钉尾部与连接棒的下端或术后严格限制腰椎的各方向活动尤其是旋转,以减小两部位的应力,降低螺钉疲劳断裂的可能性。

关 键 词:下段胸椎  侧前方固定  有限元分析  生物力学  
收稿时间:2009-09-23

The finite element analysis of anterior screw fixation on lower thoracic vertebra
LI Xiao-he,YOU Bo,LI Shao-hua,et al..The finite element analysis of anterior screw fixation on lower thoracic vertebra[J].Chinese Journal of Clinical Anatomy,2010,28(2):214.
Authors:LI Xiao-he  YOU Bo  LI Shao-hua  
Institution:Department of Anatomy, Southern Medical University, Guangzhou 510515, China
Abstract:Objective To develop a 3-D finite element (FE) model of anterior screw fixation on lower thoracic vertebra, evaluate and modify the stress of screw and the stick. Methods The geometrical model was created by Mimics13.0 based on CT data of T_(11~12) motion segment from one adult male, and then, the above models were imported into the Ansysl 1.0 for establishing the 3-D FE of anterior screw fixation on lower thoracic vertebra. The 3D FE models were further imported into Ansys11.0 and analyzed under 500N pressure loading on the upper surface of T11, and 10Nm torque loading for simulating thoracic axial compression, anteflexion, extension, lateral bending and rotation. The Von mises stress of screws and stick were recorded and analyzed statistically the difference of different stress distribution of the screws and stick. Results It was obviously that, the Von mises of the screw concentrated on the tail of screws, with the bigger stress at the inferior part than that at the superior part. Rotation movement resulted in breakage of the tails of screw and lower part of stick. Conclusions Anterior screw fixation system on lower thoracic vertebra will thicken the tails of screws and lower segment of stick. It is necessary to limit patients' activities by a waist-brace protection after operation.
Keywords:Lower thoracic vertebra  Anterior fixaion  Finite element analysis  Biomechanics
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《中国临床解剖学杂志》浏览原始摘要信息
点击此处可从《中国临床解剖学杂志》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号