首页 | 本学科首页   官方微博 | 高级检索  
     

射频导管消融治疗顽固性频发室性早搏伴短阵室性心动过速的体会
引用本文:宋治远,庄国强,舒茂琴,何国祥,迟路湘,胡厚源,仝识非,程训民,冉擘力,姚青,史光鉴. 射频导管消融治疗顽固性频发室性早搏伴短阵室性心动过速的体会[J]. 中国心脏起搏与心电生理杂志, 2003, 17(5): 352-353
作者姓名:宋治远  庄国强  舒茂琴  何国祥  迟路湘  胡厚源  仝识非  程训民  冉擘力  姚青  史光鉴
作者单位:第三军医大学西南医院心内科,重庆市介入心脏病学研究所,重庆,400038
摘    要:报道 2 5例 (男 14例、女 11例 ,年龄 15~ 6 7岁 )顽固性频发室性早搏 (简称室早 )伴短阵室性心动过速 (简称室速 )接受RFCA的治疗结果。采用心室激动顺序与起搏标测法进行室早标测定位 ,标测到室早最早激动点较体表心电图QRS波提前 30ms以上或消融电极起搏心电图QRS波图形与室早图形完全一致时放电消融。结果 :2 5例患者室早起源分别为右室流出道 12例、右室心尖部 5例、左室游离壁 5例、左室近后间隔部 3例。 2 5例中 2 1例成功 (包括 1例频发室早伴短阵多形性室速患者 ) ,成功率为 84 % ,无并发症发生。结论 :RFCA治疗频发单形性室早伴短阵室速安全、有效。

关 键 词:心血管病学  室性早搏  室性心动过速  导管消融,射频电流
文章编号:1007-2659(2003)05-0352-02
修稿时间:2003-07-28

Radiofrequency Catheter Ablation Treated Symptomatic Frequencey Ventricular Premature Beat With Paroxysmal Unsustained Ventricular Tachycardia
SONG Zhi-yuan,ZHUANG Guo-qiang,SHU Mao-qing,et al.. Radiofrequency Catheter Ablation Treated Symptomatic Frequencey Ventricular Premature Beat With Paroxysmal Unsustained Ventricular Tachycardia[J]. Chinese Journal of Cardiac Pacing and Electrophysiology, 2003, 17(5): 352-353
Authors:SONG Zhi-yuan  ZHUANG Guo-qiang  SHU Mao-qing  et al.
Affiliation:SONG Zhi-yuan,ZHUANG Guo-qiang,SHU Mao-qing,et al. Department of Cardiology,Southwest Hospital,Third Military Medical University,Chongqing 400038,China
Abstract:We resport the treatment result of 25 patients (M/F 14/11, 15 to 67 years old) who were treated by radiofrequency catheter ablation (RFCA) with symptomatic frequencey ventricular premature beat (VPB) accompanied with paroxysmal non-sustained ventricular tachycardia(VT). The way of ventricular excited subsequently and pace-mapping were used to map and locate the site of VPB origin, when the site of origin,whose the earliest excitation point of VPB was earlier 30 seconds than QRS waves of surface ECG, or QRS waves of ablation electrode pacing electrogram was complete coincidence with VPB,was found radiofrequenay current was deliveried. Result: Among 25 patients,the VPB originated from right ventricular outflow tract in 12 patients, from right ventricular apex in 5 patients, from left free wall in 4 patients, from left posterior septum in 3 patients. The VPB successfully ablated in 21 of 25 patients without complication, including 1 patient with frequency monomorphic VPB accompanied with non-sustained polymorphic VT. The success rate was 84%. Conclusion: RFCA is an effective and safe for frequent monomorphic ventricular ectopic beats accompanied with non-sustained VT.
Keywords:Ventricular premature beat Ventricular tachycardia Catheter ablation   radiofrequency current
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号