首页 | 本学科首页   官方微博 | 高级检索  
     


Obturator neuropathy: an adverse outcome of a trans-obturator vaginal mesh to repair pelvic organ prolapse
Authors:Ornella Lam Van Ba  Laurent Wagner  Renaud de Tayrac
Affiliation:1. Department of Urology, N?mes University Hospital, N?mes, France
2. Department of Gynecology and Obstetrics, N?mes University Hospital, N?mes, France
3. Service de Gynécologie Obstétrique, H?pital Carémeau, Centre Hospitalier Universitaire de N?mes, Place du Professeur Debré, 30029, N?mes Cedex 9, France
Abstract:
We report a case of obturator neuropathy induced by trans-obturator vaginal mesh surgery for symptomatic cystocele. Initial electromyography excluded genito-femoral and pudendal nerve deficiency. Typical clinical arguments for severe obturator neuropathy at physical examination led to vaginal revision surgery with hemi-resection of the mesh to the ischio-pubic branch. This fully relieved obturator-induced pain and reversed adductor muscle motor deficiency.
Keywords:
本文献已被 SpringerLink 等数据库收录!