首页 | 本学科首页   官方微博 | 高级检索  
     


Determination of the solute removal index for urea by using a partial spent dialysate collection method
Authors:YL Cheng  CC Shek  FK Wong  KS Choi  KF Chau  TS Ing  CS Li
Affiliation:Department of Medicine, Queen Elizabeth Hospital, Hong Kong, China. chengsyl@netvigator.com
Abstract:
In 22 hemodialysis patients, during a dialysis session, the solute removal index (SRI) for urea obtained from the use of a partial spent dialysate collection method was compared with that derived from the use of a total spent dialysate collection technique. The partial spent dialysate collection method was used to harvest a small representative sample of the total spent dialysate. The volumes of spent dialysate collected by the partial and the total spent dialysate collection methods were 1.7 +/- 0.4 L and 129.6 +/- 15.3 L, respectively. The total amount of urea nitrogen removed by dialysis as estimated by the partial spent dialysate collection method was similar to that determined by the total spent dialysate collection approach. As a result, the SRI value for urea obtained by the partial spent dialysate collection method (namely, 63% +/- 8%) correlated very well (r = 0.95, P < 0.001) with that derived by the total spent dialysate collection technique (namely, 62% +/- 8%). Our data suggest that it is feasible to use a simple partial spent dialysate collection method to obtain SRI results in patients treated with hemodialysis.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏