Measurement of cardiac output with non-invasive Aesculon impedance versus thermodilution
Authors:Petter Hedelin  Erik Agger  Björn Ekmehag  Göran Rådegran
Institution:1. GoRadLab, The ?resund Cardiovascular Research Collaboration, The Clinic for heart Failure and valvular heart disease, Department of Cardiology, Lund University and Sk?ne University Hospital, Sweden;2. The Copenhagen Muscle Research Centre, Rigshospitalet, Copenhagen, Denmark
Abstract:Background: This study compared the non‐invasive thoracic electrical bioimpedance Aesculon® technique (TEBAesculon) with thermodilution (TD) to evaluate whether TEBAesculon may offer a reliable means for estimating cardiac output (CO) in humans. Material and method: Cardiac output was measured with TD and TEBAesculon in 33 patients, with a mean age ± SEM of 59 ± 2·7 years, that underwent right heart catheterization for clinical investigation of pulmonary hypertension or severe heart failure. Four to five CO measurements were performed with each technique simultaneously in 33 patients at rest, 11 during exercise and seven during NO inhalation. Result: Cardiac output correlated poorly between TEBAesculon and TD at rest (r = 0·46, P<0·001), during exercise (r = 0·35, P<0·013) and NO inhalation (r = 0·41, P<0·017). CO was higher for TEBAesculon than TD with 0·86 ± 0·14 l min?1 at rest (P<0·001) and 2·95 ± 0·69 l min?1 during exercise (P<0·003), but similar during NO inhalation, with a tendency (P<0·079) to be 0·44 ± 0·19 l min?1 higher for TEBAesculon than TD. CO increased from rest to exercise for TEBAesculon and TD with 6·11 ± 0·6 l min?1 (P<0·001) and 3·91 ± 0·36 l min?1 (P<0·001), respectively; an increase that was higher (P<0·002) for TEBAesculon than TD. During NO inhalation, compared to rest, CO decreased for TEBAesculon with 0·62 ± 0·11 l min?1 (P<0·002), but not significantly for TD with 0·21 ± 0·12 l min?1 (P<0·11). Bland–Altman analysis showed a poor agreement between TEBAesculon and TD. Conclusion: TEBAesculon overestimated CO compared to TD with ~17% at rest and ~34% during exercise, but the techniques showed similar results during NO inhalation. CO, furthermore, correlated poorly between TEBAesculon and TD. TEBAesculon may at present not replace TD for reliable CO measurements in humans.
Keywords:exercise  heart failure  NO inhalation  pulmonary hypertension  thoracic electrical bioimpedance
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号