Implantation of a 29 mm sapien XT valve in a pediatric patient with an unstented right ventricular outflow tract |
| |
Authors: | Abraham Rothman MD Alvaro Galindo MD William N. Evans MD |
| |
Affiliation: | 1. Children's Heart Center, Pediatric Cardiology Division, Las Vegas, Nevada;2. School of Medicine, Department of Pediatrics, Division of Cardiology, University of Nevada, Las Vegas, Nevada |
| |
Abstract: | We describe a 29 mm Sapien XT valve implantation in a 10‐year‐old girl with repaired Tetralogy of Fallot, severe pulmonary regurgitation, and right ventricular dilatation, using the NovaFlex+ delivery system and the expandable introducer eSheath, without pre‐stenting of the right ventricular outflow tract. © 2015 Wiley Periodicals, Inc. |
| |
Keywords: | tetralogy of fallot pulmonary regurgitation Sapien valve |
|
|