通用型脊柱内固定系统稳定性的生物力学评价
引用本文:Li SG,Qiu GX,Tian Y,Lin J,Weng XS,Wang YP,Zhao WD,Huang WH. 通用型脊柱内固定系统稳定性的生物力学评价[J]. 中华外科杂志, 2003, 41(8): 581-585
作者姓名:Li SG  Qiu GX  Tian Y  Lin J  Weng XS  Wang YP  Zhao WD  Huang WH
作者单位:1. 100730,北京,中国医学科学院北京协和医院骨科
2. 第一军医大学医学生物力学实验室
基金项目:卫生部科学研究课题基金资助项目 (98 1 0 3 )
摘    要:
目的 评价通用型脊柱内固定系统经椎弓根内固定装置的生物力学稳定性。 方法取 12具正常成人新鲜尸体T12 ~S3 节段脊柱标本 ,制成L2 3 、L4 5滑脱模型 ,测试标本在正常、滑脱、通用型脊柱内固定系统 (generalspinesystem ,GSS)与SOCON固定后、疲劳试验后、GSS与SOCON翻修后、再次疲劳试验后 6种请状况下的三维运动状况 ,比较各个工况数据的差异。 结果 L2 3 节段 ,正常状态前屈运动范围平均值为 8 3° ;制成滑脱标本后 ,运动范围平均值为 14 7° ;SOCON固定后 ,节段运动范围减至 3 0°,比正常状态的运动范围减小 ,差异有显著性意义 (P <0 0 5 ) ,说明SOCON固定后可产生明显的即刻稳定作用。疲劳试验后节段运动范围平均值为 3 6°,与正常状态比较 ,差异有显著性意义 (P <0 0 5 ) ,说明经过疲劳试验SOCON固定仍有良好的稳定作用。L4 5节段 ,正常状态前屈运动范围平均值为 8 6°;制成滑脱标本后 ,运动范围平均值为 13 7° ;GSS固定后 ,节段运动范围减至 3 2°,该节段的稳定性得到加强 ,运动范围比正常状态时还要小 ,差异有显著性意义 (P <0 0 5 ) ,说明GSS固定后可产生明显的即刻稳定作用。疲劳试验后节段运动范围平均值为 3 7°。与正常状态比较 ,差异有显著性意义 (P
关 键 词:通用型脊柱内固定系统 稳定性 生物力学 内固定器 椎弓根螺钉
修稿时间:2002-12-25

Biomechanical evaluation of the stability of General spine system
Li Shu-gang,Qiu Gui-xing,Tian Ye,Lin Jin,Weng Xi-sheng,Wang Yi-peng,Zhao Wei-dong,Huang Wen-hua. Biomechanical evaluation of the stability of General spine system[J]. Chinese Journal of Surgery, 2003, 41(8): 581-585
Authors:Li Shu-gang  Qiu Gui-xing  Tian Ye  Lin Jin  Weng Xi-sheng  Wang Yi-peng  Zhao Wei-dong  Huang Wen-hua
Affiliation:Department of Orthopaedics, Peking Union Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing 100730, China.
Abstract:
OBJECTIVE: To evaluate the biomechanical stability of Shen's instrumentation in the management of thoracolumbar fractures. METHODS: The ranges of movement (ROM) in three dimensions of twelve T(12) - S(3) specimen of fresh adult cadavers were measured sequentially in the states of normal, injured, GSS and SOCON fixation, fatigued GSS and SOCON fixation. Data were then compared. RESULTS: For the L(2 - 3) segment, the average normal ROM in flexion was 8.3 degrees. In the established spondylolisthesis models, the ROM was 14.7 degrees. After fixation with SOCON, the ROM was decreased to 3.0 degrees, indicating that SOCON fixation can produce good stability. The ROM after fatigue test was 3.6 degrees, significantly lower than that of the normal state, indicating that SOCON still produces good stability after fatigue. For the L(4 - 5) segment, the average normal ROM in flexion was 8.6 degrees. In the established spondylolisthesis models, the ROM was 13.7 degrees. After GSS fixation, the ROM was decreased to 3.2 degrees, significantly lower than that in the normal state, indicating that GSS fixation can produce good stability. ROM after fatigue test was 3.7 degrees, significantly lower than that of the normal state, indicating that GSS can produce good stability after fatigue. The ROM measurements in the other five directions were similar to those for flexion described above. CONCLUSION: GSS produces good stability for spondylolisthesis, good fatigue resistance, and can be used in pedicle screw revision surgery. There were no significant differences between GSS and SOCON.
Keywords:Spinal fracture  Internal fixators  Fracture fixation   internal  Fracture fixation