首页 | 本学科首页   官方微博 | 高级检索  
     

气相色谱法直接测定血液中乙醇的含量
引用本文:陈君,彭锋. 气相色谱法直接测定血液中乙醇的含量[J]. 检验医学与临床, 2010, 7(5): 418-418,420
作者姓名:陈君  彭锋
作者单位:四川省泸州市疾病预防控制中心,646000
摘    要:目的快速、准确检测血液乙醇含量。方法采用气相色谱法(样品不经前处理,直接进样)检测血液乙醇含量。结果乙醇线性范围0~188.7mg/100mL内相关系数r=0.9998,变异系数为小于3%,回收率97.9%~102.4%。结论气相色谱法操作简单、灵敏度高、用样量少、精密度、回收率、重现性均得到满意的结果。

关 键 词:气相色谱法  填充柱  直接进样  乙醇舍量

Determination of the ethanol content in blood by gas chromatography with direct injection
CHEN Jun,PENG Feng. Determination of the ethanol content in blood by gas chromatography with direct injection[J]. Laboratory Medicine and Clinic, 2010, 7(5): 418-418,420
Authors:CHEN Jun  PENG Feng
Affiliation:CHEN Jun,PENG Feng.Center for Disease Control , Prevention of Luzhou,Shichuan 64600,China
Abstract:Objective For detecting the ethanol content in blood accurately and guickly.Methods Gas chromatography(simples without pre-treatment and injecting directly).Results When linearity range of ethanol is between 0-188.73mg/100ml,the R is 0.9998,the coefficient of variation(CV) is less than 3% and the ratio of recycling is between 97.9-102.4%.Conclusion The method is simple to be operated,and of high sensitivity and few samples can be done.It also can obtain the precisd,results and it is also of recycling and re...
Keywords:gas chromatography  packed column  inject directly  ethanol in blood  
本文献已被 CNKI 维普 万方数据 等数据库收录!