实时三维超声心动图对维持性血液透析患者左心功能的评价
引用本文:王玲,王静,郑敏,张春梅,李婵. 实时三维超声心动图对维持性血液透析患者左心功能的评价[J]. 吉林大学学报(医学版), 2010, 36(4): 779-782
作者姓名:王玲  王静  郑敏  张春梅  李婵
作者单位:1.哈尔滨医科大学附属第一医院超声科,黑龙江 哈尔滨 150001;2.中国人民解放军第211医院超声科,黑龙江 哈尔滨 150001
基金项目:黑龙江省科技厅科技攻关项目资助课题 
摘    要:目的:以磁共振显像(MRI)技术为对照标准,探讨实时三维超声心动图(RT-3DE)评价维持血液透析(MHD)患者的左心室容积(LVV)和射血分数(LVEF)的可行性与准确性。方法:MHD患者48例,采用RT-3DE采集其LVV和LVEF,同时应用二维超声心动图Simpson’s法M-Teichholz法进行检测,将3种方法的检测值与MRI所检测的数据进行比较。结果:①RT-3DE容积检测值和MRI测量的LVV有良好的相关性(r=0.90,P<0.001),配对t检验表明,两者检测值之间差异无显著性(P>0.05)。②在心腔变形时,M-Teichholz、Simpson’s法所测左室舒张末期容积(LVEDV)和左室收缩末期容积(LVESV)均高于或低于RT-3DE检测值,差异均有显著性(均P<0.05)。结论:RT-3DE可准确测量正常心腔及心腔变形情况下的LVV,在心腔变形情况下,RT-3DE较M-Teichholz、Simpson’s 法测得的LVV及LVEF数据准确性高。

关 键 词:维持性血液透析;实时三维超声心动图;左室容积;核磁共振成像  
收稿时间:2010-04-08

Evaluation of left ventricular function in maintained hemodialysis patients using real-time three-dimensional echocardiography
WANG Ling,WANG Jing,ZHENG Min,ZHANG Chun-mei,LI Chan. Evaluation of left ventricular function in maintained hemodialysis patients using real-time three-dimensional echocardiography[J]. Journal of Jilin University: Med Ed, 2010, 36(4): 779-782
Authors:WANG Ling  WANG Jing  ZHENG Min  ZHANG Chun-mei  LI Chan
Affiliation:1. Department of Ultrasonography,First Affiliated Hospital,Harbin Medical University,Harbin 150001,China|2. Department of Ultrasonography,No.211 Hospital of PLA,Harbin 150001,China
Abstract:Objective Using magnetic resonance imaging(MRI)technique as control standard,to explore the feasibility and accuracy of true real-time three-dimensional volume quantitative techniques(RT-3DE)in evaluation of the left ventricular volume(LVV)and left ventricular ejection fraction(LVEF)of the maintained hemodialysis(MHD)patients.Methods 48 MHD patients were enrolled in this study.RT-3DE was used to detect the LVV and LVEF,while Simpson's method and M-Teichholz method were used at the same time.The results of the three methods were compared with the data measured by MRI.Results ①The data measured by RT-3DE method showed a highly positive correlation with the LVV detected by MRI(r=0.90,P<0.001),but there was no significant difference between the two methods(P>0.05).②When heart cavity deformed,the results of left ventricular end-diastolic volume(LVEDV)and left ventricular end-systolic volume(LVESV)measured by M-Teichholz method and Simpson's method were higher or lower than the data measured by RT-3DE method,and the differences were statistically significant(all P<0.05).Conclusion RT-3DE can accurately measure the volume of normal cardiac chambers and the left ventricular cavity deformation volume.The result of RT-3DE has higher accuracy compared with Simpson's method and M-Teichholz method.
Keywords:maintained hemodialysis  real-time three-dimensional echocardiography  left ventricular volume  magnetic resonance imaging