首页 | 本学科首页   官方微博 | 高级检索  
     


Incorporation of the fluoroless C-Arm Trainer at the American Urological Association hands on training percutaneous renal access
Authors:Yasser?A.?Noureldin,David?M.?Hoenig,Philip?Zhao,Sammy?E.?Elsamra,Joshua?Stern,Geoffrey?Gaunay,Piruz?Motamedinia,Zeph?Okeke,Ardeshir?R.?Rastinehad,Robert?M.?Sweet  mailto:rsweet@uw.edu"   title="  rsweet@uw.edu"   itemprop="  email"   data-track="  click"   data-track-action="  Email author"   data-track-label="  "  >Email author
Affiliation:1.Department of Surgery, WWAMI Institute for Simulation in Healthcare (WISH),University of Washington,Seattle,USA;2.Department of Urology, Benha Faculty of Medicine,Benha University,Benha,Egypt;3.The Smith Institute for Urology,Hofstra Northwell School of Medicine,New Hyde Park,USA;4.Department of Urology,NYU School of Medicine,New York,USA;5.Department of Urology, Montefiore Medical Center,Albert Einstein College of Medicine,Bronx,USA;6.Yale University School of Medicine,New Haven,USA;7.Icahn School of Medicine at Mt. Sinai,New York,USA;8.Department of Urology,University of Washington,Seattle,USA
Abstract:

Objectives

To assess for usefulness and validity evidence for incorporating the C-Arm Trainer (CAT) simulator into the annual AUA hands on course for training percutaneous nephrolithotomy (PCNL).

Materials and methods

The course started with a didactic session followed by four stations for training the “bull’s eye” technique using the CAT simulator. Each station included a pre-test, 30-min practice on the simulator, and post-test. All participants were assessed using a 4-item checklist. All participants were asked to fill in a qualitative self-assessment questionnaire after the pre- and the post-test, and respond to a course evaluation questionnaire and post-course survey.

Results

A total of 38 physicians, who attended the hands on course, voluntarily participated in the study. Only 21.1% had previous practice on PCNL simulators. Compared with the results of the checklist total score and the qualitative self-assessment questionnaire scores after the pre-test, there was significant improvement in the checklist total score (p < 0.001), temporal demands (p = 0.003), situational stress (p = 0.003, and performance (0.003) after the post-test. A total of 14 (36%) participants responded to the course evaluation questionnaire, 50% evaluated the course as excellent, 28.6% as very good, and 21.4% as good. Unfortunately, only five (13%) participants responded to the post-course survey, 4/5 implemented the new competencies and knowledge into their practice, and 3/5 have attempted to obtain fluoroscopic guided PCA without assistance.

Conclusion

The CAT simulator was considered useful for training the percutaneous renal access procedure. There was significant improvement in the qualitative and quantitative assessment parameters after the post-test compared with the pre-test.
Keywords:
本文献已被 SpringerLink 等数据库收录!