首页 | 本学科首页   官方微博 | 高级检索  
     


A new microcellular cytotoxicity test based on calcein AM release
Authors:Xiu Ming Wang   Paul I. Terasaki   George W. Rankin Jr.   David Chia   Hui Ping Zhong  Steven Hardy
Abstract:
We present a microtest for cell-mediated immunity, based on the use of the Tarasaki tray and calcein AM vital dye. The number of target cells needed has been reduced to 500 per test with a corresponding tenfold reduction in the number of effector cells needed. Results were read at the rate of 1 second per test using a fluorimeter attached to a microscope. Each reaction was also confirmed visually with the use of ethidium bromide as a counterstain for dead cells. The calcein AM dye used to stain the living cells was shown to have a low spontaneous leakage rate—less than 15% in 4 hours at 37°C. Dilutions of targets stained by calcein AM had a linear relationship with measured fluorescence values. NK cells, LAKs, and CTLs were readily detectable by this microtest. Quantitation of killing and kinetic analysis was readily performed with this test system. A significant positive correlation to 51Cr-release results was found. We conclude that the microtest should find wide application in studies of cell-mediated immunity.
Keywords:
本文献已被 ScienceDirect 等数据库收录!