首页 | 本学科首页   官方微博 | 高级检索  
     


Analysis of CO2 monitoring data demonstrates poor ventilation rates in Albanian schools during the cold season
Authors:Otto Hänninen  Nuno Canha  Alexandra V. Kulinkina  Ilir Dume  Agron Deliu  Elida Mataj  Arben Lusati  Michal Krzyzanowski  Andrey I. Egorov
Affiliation:1.National Institute for Health and Welfare (THL),Kuopio,Finland;2.Centro de Ciências e Tecnologias Nucleares, Instituto Superior Técnico,Universidade de Lisboa,Bobadela LRS,Portugal;3.Department of Environment and Planning, CESAM–Centre for Environmental and Marine Studies,University of Aveiro,Aveiro,Portugal;4.Tufts University School of Engineering,Medford,USA;5.National Public Health Institute,Tirana,Albania;6.World Health Organization, European Centre for Environment and Health,Bonn,Germany;7.King’s College London,London,UK
Abstract:
Poor ventilation in schools is associated with accumulation of indoor-generated pollutants, which is associated with “stuffy” air, elevated risk of infectious diseases and impaired learning outcomes. This survey in Albania was conducted as part of WHO’s efforts to facilitate assessments of indoor air quality and other environmental factors in schools in the European Region. The survey was conducted in 36 classrooms in 12 middle schools (eight urban and four rural) from December 2011 through March 2012. In each school, carbon dioxide (CO2) was continuously measured in three classrooms during one school week. Ventilation rates during classes were estimated using the build-up and steady-state mass balance equations utilizing CO2 concentration data, classroom occupancy and classroom volume. All 12 schools had gravimetric ventilation systems. Heating systems were absent or not operational in most schools. Average classroom temperatures during lessons varied from 9.1 to 14.4 °C (median 11.7 °C) with lower temperature associated with poorer ventilation. Weekly average CO2 levels during classes ranged from 1286 to 5546 ppm (median 2776 ppm) while average ventilation rates ranged from 0.8 to 3.6 (median 1.8) litres per second per person. Classrooms with indoor combustion heaters had higher indoor temperature, lower CO2 levels and higher levels of carbon monoxide (CO). WHO guidelines on 1- and 8-h CO exposure levels were exceeded in one classroom. Classroom CO2 levels were substantially above and ventilation rates below existing national and international guidelines. Detrimental impacts of poor ventilation on health and learning outcomes are likely to be substantial in Albanian schools during the cold season. Indoor temperature in most classrooms was below the commonly recommended levels.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号