首页 | 本学科首页   官方微博 | 高级检索  
检索        

液体芯片技术定量测定人体血清CEA、AFP、NSE和tPSA
引用本文:梁惠仪,彭娟,李明,吴英松.液体芯片技术定量测定人体血清CEA、AFP、NSE和tPSA[J].分子诊断与治疗杂志,2010,2(4):266-271.
作者姓名:梁惠仪  彭娟  李明  吴英松
作者单位:南方医科大学生物技术学院,广东,广州,510515
基金项目:国家高技术研究发展计划(863计划)
摘    要:目的 应用液体芯片技术,联合定量测定人体血清癌胚抗原(CEA)、甲胎蛋白(AFP)、神经元特异性烯醇化酶(NSE)和前列腺特异性抗原(tPSA),并对其临床应用进行评价.方法 制备交联微球以及生物素标记抗体,利用双抗体夹心法对60个血清样本进行测定,并将其结果与化学发光免疫分析法(CLIA)作比较.结果 同时检测CEA、AFP、tPSA、NSE的线性范围分别为0.078~200 ng/mL、0.030~30.3 ng/mL、0.007~7.5 ng/mL、0.146~75 ng/mL;最低检测限为26.0 pg/mL、19.7 pg/mL、4.9 pg/mL、73.2 pg/mL;批内精密度CV〈9.0%,批间精密度CV〈13.2%;检测结果与CLIA测值的相关系数r分别为0.986、0.979、0.964、0.958(P〈0.001).结论 液体芯片技术是一种具有极大优势的新型检测技术.该技术打破传统测定技术每次只能测定一个指标的限制,并且具有高通量、高灵敏度、检测时间短、样本用量少等特点.

关 键 词:液相芯片技术  肿瘤标志物  总前列腺特异性抗原(tPSA)  高通量  重复性

Quantitative determination of carcinoembryonic antigen(CEA),alpha fetoprotein(AFP),neuron specific enolase(NSE)and total prostate specific antigen(tPSA)by multiplexed bead-based immunoassay
LIANG Huiyi,PENG Juan,LI Ming,WU Yingsong.Quantitative determination of carcinoembryonic antigen(CEA),alpha fetoprotein(AFP),neuron specific enolase(NSE)and total prostate specific antigen(tPSA)by multiplexed bead-based immunoassay[J].Journal of Molecular Diagnosis and Therapy,2010,2(4):266-271.
Authors:LIANG Huiyi  PENG Juan  LI Ming  WU Yingsong
Institution:* (The School of Biotechnology, Southern Medical University, Guangdong, Guangzhou 510515, China)
Abstract:Objective To measure the levels of carcinoembryonic antigen (CEA), alpha fetoprotein (AFP), neuron specific enolase (NSE) and total prostate specific antigen (tPSA) in human serum using multiplexed bead-based immunoassay, finally carry out valuation on its clinical practice. Methods Antibody-conjugated microspheres and biotinylated detection antibodies were prepared. The levels of CEA, AFP, NSE and tPSA in clinical serum samples were also measured using a sandwich immunoassay, and compared the performance of this method with chemiluminescence immunoassay(CLIA). Results Dynamic range were 0.039~400 ng/mL, 0.030~121 ng/mL, 0.007~30 ng/mL, 0.146-300 ng/mL, and lower limits of detection were 26.0 pg/mL, 19.7 pg/mL, 4.9 pg/mL, 73.2 pg/mL for CEA, AFP, tPSA and NSE, respectively. Intra-assay variances were less than 9%, and inter-assay variances were less than 14%. Correlation coefficients(r) were 0.986, 0.979(P〈0.001, n=64), 0.964(P〈0.001, n=60), 0.958(P〈0.001, n=64) compared with CLIA for CEA, AFP, tPSA and NSE, respectively. Result obtained from multiplexed bead-based immunoassay was compatible with chemiluminescence immunoassay(CLIA). However, only 1 microtiter of serum and 2 to 3 hours were required for the multiplexed bead-based immunoassay. Conclusion The multiplexed bead-based immunoassay is a sensitive, reproducible and a high-throughput method. This method may further be developed for clinical application.
Keywords:Suspension array technology  Tumor markers  Total prostate specific antigen  High- throughput method  Repeatability
本文献已被 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号