首页 | 本学科首页   官方微博 | 高级检索  
     


Treatment of Two-Part Proximal Humerus Fractures: Intramedullary Nail Compared to Locked Plating
Authors:Nikola Lekic MS  Nicole M. Montero MD  Richelle C. Takemoto MD  Roy I. Davidovitch MD  Kenneth A. Egol MD
Affiliation:1. Georgetown University School of Medicine, Washington, DC, 20057, USA
2. New York University Hospital for Joint Diseases, 301 E 17th St, New York, NY, 10003, USA
Abstract:

Background

Two-part proximal humerus fractures are common orthopedic injuries for which surgical intervention is often indicated. Choosing a fixation device remains a topic of debate.

Purpose

The purpose of this study is to compare two methods of fixation for two-part proximal humerus fractures, locking plate (LP) with screws versus intramedullary nailing (IMN), with respect to alignment, healing, patient outcomes, and complications. To our knowledge, a direct comparison of these two devices in treating two-part proximal humerus fractures has never before been studied. We hope that our results will help surgeons assess the utility of LP versus IMN.

Methods

A retrospective chart review was performed on 24 cases of displaced two-part surgical neck fractures of the humerus. Twelve shoulders were treated using IMN fixation and 12 others were fixated with LP. Data collected included sociodemographic, operative details, and postoperative care and function.

Results

Radiographic comparison of fixation demonstrated an average neck-shaft angle of 124° and 120° in the IMN group and LP group, respectively. Adjusted postoperative 6-month follow-up range of motion was 134° of forward elevation in the IMN group and 141 in the LP group. The differences in range of motion and in complication rates were not found to be significant.

Conclusions

Our results suggest that either LP fixation or IMN fixation for a two-part proximal humerus fracture provides acceptable fixation and results in a similar range of shoulder motion. Although complication rates were low and insignificant between the two groups, a trend toward increased complications in the IMN group is noted.
Keywords:two-part proximal humerus fracture   locking plate   intramedullary nail   outcomes of proximal humerus fractures
本文献已被 SpringerLink 等数据库收录!