首页 | 本学科首页   官方微博 | 高级检索  
     


Lyoluminescence dosimetry in photon and fast neutron beams
Authors:K J Puite  D L Crebolder
Abstract:
The lyoluminescence (LL) technique using mannose, a monosaccharide, is described. Dose-response curves for 60Co-gamma-rays (5 rad to 120 krad), fission neutrons, 5.3 MeV and 15 MeV neutrons (100 rad to 20 krad) have been measured. The close tissue-equivalence of mannose makes this material well suited for dosimetric use in low energy X-ray fields for radiotherapy and radiobiology. It also provides a cheap, simple and reproducible dosemeter in industrial applications of radiation (sprouting inhibition of onions and potatoes; control of insect infestation). After correction for the gamma contamination of the neutron beam the LL signal per rad in ICRU muscle tissue from the neutron irradiations has been derived and the relative effectiveness of the LL signal for fast neutrons in mannose has been calculated as 0.34 +/- 0.03 (fission neutrons), 0.63 +/- 0.07 (5.3 MeV neutrons) and 0.74 +/- 0.05 (15 MeV neutrons). These results are compared with data from other systems. It is concluded that mannose can be used as a transfer system in neutron dosimetry, if its variation in sensitivity with neutron energy is taken into account.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号