首页 | 本学科首页   官方微博 | 高级检索  
     

用蒙特卡罗方法模拟实验体内金属植入物对放疗剂量分布影响
引用本文:倪昕晔,汤晓斌,张志明,顾卫东,耿长冉,林涛,宋浩磊,刘茜,孙苏平,陈达. 用蒙特卡罗方法模拟实验体内金属植入物对放疗剂量分布影响[J]. 中华放射肿瘤学杂志, 2011, 20(5). DOI: 10.3760/cma.j.issn.1004-4221.2011.05.020
作者姓名:倪昕晔  汤晓斌  张志明  顾卫东  耿长冉  林涛  宋浩磊  刘茜  孙苏平  陈达
作者单位:1. 213003 南京医科大学附属常州第二人民医院;南京航空航天大学核科学与工程系
2. 南京航空航天大学核科学与工程系
3. 213003,南京医科大学附属常州第二人民医院
基金项目:江苏省常州市社会发展项目
摘    要:目的 用蒙特卡罗(MC)模拟实验体内植入金属物后的百分深度剂量变化。方法 用6MVX线照射水下 5 cm处0.4 cm厚金属植入物,对有无金属植入物百分深度剂量变化进行MC方法模拟实验并比较结果。结果 6MVX线照射置入不锈钢板、钛合金板比不用植入物时入射面剂量分别增加19.6%、15.7%,不锈钢板、钛合金板入射面0.3 cm以外影响<1.5%。不锈钢板、钛合金板出射面剂量分别减少8.6%、8.2%,剂量影响<1.5%时距离出射面1.2、0.9 cm。不锈钢板比钛合金板入射面剂量大3.9%,出射面剂量相似。结论 MC方法是一种能快捷、准确的计算方式,金属植入物对放疗剂量影响明显,相同条件下不锈钢对入射面剂量影响大于钛合金钢板。

关 键 词:蒙特卡罗  放射剂量  金属植入物

Impact of implanted metal plates on radiation dose distribution in vivo by Monte Carlo code
Nl Xin-ye,Tang Xiao-bing,ZHANG Zhi-ming,GU Wei-dong,GENG Chang-ran,LIN Tao,SONG Hao-lei,LIU Xi,SUN Su-ping,CHEN Da. Impact of implanted metal plates on radiation dose distribution in vivo by Monte Carlo code[J]. Chinese Journal of Radiation Oncology, 2011, 20(5). DOI: 10.3760/cma.j.issn.1004-4221.2011.05.020
Authors:Nl Xin-ye  Tang Xiao-bing  ZHANG Zhi-ming  GU Wei-dong  GENG Chang-ran  LIN Tao  SONG Hao-lei  LIU Xi  SUN Su-ping  CHEN Da
Abstract:Objective To investigate the impact of metal plate on radiation dose distribution by Monte Carlo (MC) code. Methods The metal plates with 0. 4 thick were placed in water at 5 cm, all the plate irradiated with 6 MV X-ray were simulated by MC code, SSD =100 cm. The percentage depth dose with or without metal implants were compared. Results The surface absorbed doses on incident plane of stainless steel plate and titanium plate were increased by 19. 6% and 15.7% respectively as compared water,the dose influence was less than 1.5% more than 0. 3 cm outside the incidence plane. The doses on the exit surface of stainless steel plate and titanium plate were lowered by 8. 6% and 8. 2% when compared with water, the dose impacts of this places where were from the exit surface of stainless steel plate 、titanium plate more than 1.2 cm,0. 9 cm were less than 1.5%. The surface absorbed doses on incident plane of stainless steel plate were increased by 3.9% respectively as titanium plate, the dose of the exit surface of stainless steel plate and titanium plate was similar. Conclusions MC method is a fast and accurate calculation method. The influence of metal plate on the radiotherapy dose distribution is significant. Under the such condition, the impact of stainless steel plate is much more than that of titanium alloy plate.
Keywords:Monte Carlo  Radiation dose  Metal implants
本文献已被 万方数据 等数据库收录!
正在获取相似文献,请稍候...
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号