Influence of Pulse Oximetry and Capnography on Time to Diagnosis of Critical Incidents in Anesthesia: A Pilot Study Using a Full-Scale Patient Simulator |
| |
Authors: | Samsun Lampotang J. S. Gravenstein Tammy Y. Euliano Willem L. van Meurs Michael L. Good Paul Kubilis Rod Westhorpe |
| |
Affiliation: | (1) Department of Anesthesiology, University of Florida College of Medicine, Florida, U.S.A.;(2) University of Florida Brain Institute, Florida, U.S.A.;(3) Department of Mechanical Engineering, University of Florida College of Engineering, Florida, U.S.A.;(4) Department of Electrical and Computer Engineering, University of Florida College of Engineering, Florida, U.S.A.;(5) Veterans Affairs Medical Center, Gainesville, Florida, U.S.A.;(6) Division of BioStatistics, University of Florida, Florida, U.S.A.;(7) The Royal Children's Hospital, Parkville, Melbourne, Australia |
| |
Abstract: | Objective. Many studies (outcome, epidemiological) have tested the hypothesis that pulse oximetry and capnography affect the outcome of anesthetic care. Uncontrollable variables in clinical studies make it difficult to generate statistically conclusive data. In the present study, we eliminated the variability among patients and operative procedures by using a full-scale patient simulator. We tested the hypothesis that pulse oximetry and capnography shorten the time to diagnosis of critical incidents. Methods. A simulator was programmed to represent a patient undergoing medullary nailing of a fractured femur under general anesthesia and suffering either malignant hyperthermia, a pneumothorax, a pulmonary embolism or an anoxic oxygen supply. One hundred thirteen anesthesiologists were randomly assigned to one of two groups of equal size, one with access to pulse oximetry and capnography data and the other without. Each anesthesiologist was further randomized to one of the four critical incidents. Each anesthetic procedure was videotaped. The time to correct diagnosis was measured and analyzed. Results. Based on analysis of 91 of the subjects, time to diagnosis was significantly shorter (median of 432 s vs. >480 s) for the anoxic oxygen supply scenario (p = 0.019) with pulse oximetry and capnography than without. No statistical difference in time to diagnosis was obtained between groups for the other three critical incidents. Conclusions. Simulation may offer new approaches to the study of monitoring technology. However, the limitations of current simulators and the resources required to perform simulator-based research are impediments to wide-spread use of this tool. |
| |
Keywords: | pulse oximetry capnography monitoring critical incidents simulator anoxic oxygen supply pneumothorax pulmonary embolism malignant hyperthermia |
本文献已被 SpringerLink 等数据库收录! |
|