Biomechanical evaluation of the less invasive stabilization system and the 95-degree angled blade plate for the internal fixation of distal femur Fractures in human cadaveric bones with high bone mineral density |
| |
Authors: | Zlowodzki Michael Williamson Scott Zardiackas Lyle D Kregor Philip J |
| |
Affiliation: | Department of Orthopedic Surgery, University of Minnesota, Minneapolis, USA. |
| |
Abstract: | BACKGROUND: The less invasive stabilization system (LISS) is an internal fixator that utilizes unicortical locked screws for fixation of distal femur fractures. A question is whether locked unicortical screw fixation is sufficient, when compared with a standard implant such as a blade plate. METHODS: Eight matched pairs of fresh-frozen cadaveric femora were instrumented with either the LISS or a 95-degree blade plate. A 4-cm supracondylar gap fracture model was created and all bone-implant constructs were tested to failure in axial loading. RESULTS: All constructs failed by plastic deformation of the implant. There was no significant difference between the LISS and the blade plate constructs with respect to load to failure. CONCLUSIONS: Despite unicortical fixation axial loading to failure of the LISS did not result in implant/screw pull-out neither proximally nor distally. However, there does not appear to be a biomechanical advantage of using the LISS as opposed to a blade plate in bones with high bone mineral density. |
| |
Keywords: | |
本文献已被 PubMed 等数据库收录! |
|