Abstract: | Insertion of the conventional laryngeal mask is more difficult or impossible when the patient's head and neck are in either the neutral or flexed position. The intubating laryngeal mask is best inserted when the patient's head is supported by a pillow, without placing the head and neck into the Magill position; therefore, insertion of this modified mask may be less difficult than the conventional mask in the patient with a flexed neck. We report a case of successful insertion of the intubating laryngeal mask and subsequent tracheal intubation through the mask using a fibre-optic bronchoscope, in a patient with a flexed neck in whom tracheal intubation using several methods had been difficult previously. |
| |
Keywords: | Equipment fibre-optic bronchoscope, laryngeal mask Intubation difficult Intubation, tracheal technique, difficult |