首页 | 本学科首页   官方微博 | 高级检索  
检索        


Selected RD1 Peptides for Active Tuberculosis Diagnosis: Comparison of a Gamma Interferon Whole-Blood Enzyme-Linked Immunosorbent Assay and an Enzyme-Linked Immunospot Assay
Authors:Delia Goletti  Donatella Vincenti  Stefania Carrara  Ornella Butera  Federica Bizzoni  Giuliana Bernardini  Massimo Amicosante  and Enrico Girardi
Institution:Second Division, Health Department of the National Institute for Infectious Diseases (INMI) Lazzaro Spallanzani,1 Translational Research Unit, INMI,2 Department of Internal Medicine, University of Tor Vergata,4 Epidemiology Department, INMI, Rome,5 Division of Infectious Diseases, Ospedale Belcolle, Viterbo, Italy3
Abstract:We recently set up a gamma interferon (IFN-γ) enzyme-linked immunospot assay (ELISPOT), using selected early secreted antigenic target 6 (ESAT-6) peptides, that appears specific for active tuberculosis (A-TB). However, ELISPOT is difficult to automate. Thus, the objective of this study was to determine if the same selected peptides may be used in a technique more suitable for routine work in clinical laboratories, such as whole-blood enzyme-linked immunosorbent assay (WBE). For this purpose, 27 patients with A-TB and 41 control patients were enrolled. Our WBE, using the already described selected peptides from ESAT-6 plus three new ones from culture filtrate protein 10, was performed, and data were compared with those obtained by ELISPOT. Using our selected peptides, IFN-γ production, evaluated by both WBE and ELISPOT, was significantly higher in patients with A-TB than in controls (P < 0.0001). Statistical analysis showed a good correlation between the results obtained by WBE and ELISPOT (r = 0.80, P < 0.001). To substantiate our data, we compared our WBE results with those obtained by QuantiFERON-TB Gold, a whole-blood assay based on region of difference 1 (RD1) overlapping peptides approved for TB infection diagnosis. We observed a slightly higher sensitivity with QuantiFERON-TB Gold than with our WBE (89% versus 81%); however, our test provided a better specificity result (90% versus 68%). In conclusion, results obtained by WBE based on selected RD1 peptides significantly correlate with those generated by ELISPOT. Moreover, our assay appears more specific for A-TB diagnosis than QuantiFERON-TB Gold, and thus it may represent a complementary tool for A-TB diagnosis for routine use in clinical laboratories.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号