首页 | 本学科首页   官方微博 | 高级检索  
检索        

FP-7型与S-2型Ahmed青光眼引流阀在难治性青光眼中的短期疗效
引用本文:白玉婧,李轶擎,柴芳,杨雪娇,张一翀,魏雁涛,黄晶晶,葛坚,卓业鸿.FP-7型与S-2型Ahmed青光眼引流阀在难治性青光眼中的短期疗效[J].中华医学杂志(英文版),2011,124(8):1128-1133.
作者姓名:白玉婧  李轶擎  柴芳  杨雪娇  张一翀  魏雁涛  黄晶晶  葛坚  卓业鸿
作者单位:State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, Guangdong 510060, China
基金项目:the grants from the National Basic Research Program of China,the National Natural Science Foundation of China,Guangdong Province Universities and Colleges 2010 Pearl River Scholar Funded Scheme and the Science and Technology Planning Project of Guangdong Province
摘    要:
Background  Ahmed glaucoma valves (AGV) has been used for decades, but there is no detailed report about the efficacy of AGV in Chinese glaucoma patients. This study aimed to compare the intraocular pressure (IOP) lowering efficacy and side effects of S-2 polypropylene and PF-7 silicone AGV implantation in Chinese refractory glaucoma patients.
Methods  Patients were divided into S-2 model AGV group and FP-7 model AGV group. The complete and qualified surgical success rate, change of IOP, number of anti-glaucoma medications used and postoperative complications were recorded and analyzed.
Results  Average follow-up time was comparable between two groups. IOP was reduced from (37.9±12.7) mmHg preoperatively to (17.3±5.3) mmHg at the last follow-up in S-2 group and reduced from (39.9±14.4) mmHg to (17.7±4.9) mmHg in FP-7 group. Anti-glaucoma medications were reduced from 3.8±0.2 to 1.5±0.2 in S-2 group, and 3.5±0.2 to 0.7±0.2 in FP-7 groups. The cumulative success rates were comparable in two groups, which were 61.2% and 72.1% in S-2 group and FP-7 group respectively. When IOP reduction criteria was used, complete success rates were 30.6% and 51.2% for S-2 and FP-7 groups, and qualified success rates were 86.1% and 92.7% separately. In both groups, the major complication was hypotony, and the previous trabeculectomy of patients was the major risk factor for surgery failure.
Conclusions  In this short-term retrospective study, S-2 AGV is showed at least as effective as FP-7 AGV in IOP reduction, but associated with higher rate of complications. Previous trabeculectomy is a principle risk factor for AGV implantation failure. These clinical outcomes are important for converting use of the FP-7 silicon AGV in Chinese refractory glaucoma patients.


关 键 词:青光眼  患者  治疗  植入  短期  手术成功率  毫米汞柱  AGV

Comparison of FP-7 and S-2 Ahmed glaucoma valve implantation in refractory glaucoma patients for short-term follow up
Bai Yu-jing,Li Yi-qing,Chai Fang,Yang Xue-jiao,Zhang Yi-chong,Wei Yan-tao,Huang Jing-jing,Ge Jian,Zhuo Ye-hong.Comparison of FP-7 and S-2 Ahmed glaucoma valve implantation in refractory glaucoma patients for short-term follow up[J].Chinese Medical Journal,2011,124(8):1128-1133.
Authors:Bai Yu-jing  Li Yi-qing  Chai Fang  Yang Xue-jiao  Zhang Yi-chong  Wei Yan-tao  Huang Jing-jing  Ge Jian  Zhuo Ye-hong
Institution:State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, Guangdong, China.
Abstract:Background Ahmed glaucoma valves (AGV) has been used for decades, but there is no detailed report about the efficacy of AGV in Chinese glaucoma patients. This study aimed to compare the intraocular pressure (IOP) lowering efficacy and side effects of S-2 polypropylene and PF-7 silicone AGV implantation in Chinese refractory glaucoma patients.Methods Patients were divided into S-2 model AGV group and FP-7 model AGV group. The complete and qualified surgical success rate, change of IOP, number of anti-glaucoma medications used and postoperative complications were recorded and analyzed.Results Average follow-up time was comparable between two groups. IOP was reduced from (37.9±12.7) mmHg preoperatively to (17.3±5.3) mmHg at the last follow-up in S-2 group and reduced from (39.9±14.4) mmHg to (17.7±4.9)mmHg in FP-7 group. Anti-glaucoma medications were reduced from 3.8±0.2 to 1.5±0.2 in S-2 group, and 3.5±0.2 to 0.7±0.2 in FP-7 groups. The cumulative success rates were comparable in two groups, which were 61.2% and 72.1% in S-2 group and FP-7 group respectively. When IOP reduction criteria was used, complete success rates were 30.6% and 51.2% for S-2 and FP-7 groups, and qualified success rates were 86.1% and 92.7% separately. In both groups, the major complication was hypotony, and the previous trabeculectomy of patients was the major risk factor for surgery failure.Conclusions In this short-term retrospective study, S-2 AGV is showed at least as effective as FP-7 AGV in IOP reduction, but associated with higher rate of complications. Previous trabeculectomy is a principle risk factor for AGV implantation failure. These clinical outcomes are important for converting use of the FP-7 silicon AGV in Chinese refractory glaucoma patients.
Keywords:glaucoma  drainage device  Ahmed  refractor glaucoma
本文献已被 维普 万方数据 PubMed 等数据库收录!