Chemo-mechanical dentine caries removal with Carisolv using a rotating brush. |
| |
Authors: | C Meller A W Nourallah C Heyduck H Steffen C H Splieth |
| |
Affiliation: | Department of Preventive and Pediatric Dentistry, Centre of Oral Health, Ernst-Moritz-Arndt University, Greifswald, Germany. |
| |
Abstract: | ![]() AIM: The aim of this study was to assess the efficacy of removing dentine caries using carbide burs, Carisolv with hand instruments and Carisolv in combination with a new mechanical excavation method using a rotating brush. METHODS: 36 extracted permanent teeth, with dentine caries, were assigned into 3 groups according to caries removal technique. Caries removal was monitored by checking the properties of the dentine with a dental explorer. After embedding and sectioning (400 microm), remaining caries was assessed by using a caries detector. In microscope images (7x) of the samples, the mean stain depth of the remaining carious tissue per tooth was calculated by AnalySIS computer software. RESULTS: Four to 8 applications (mean time = 10.9 min) of Carisolv were necessary for caries removal with the new method using rotating brushes. The mean thickness of residual dentine caries by this procedure (226 microm, +/- 136) was higher than the one using Carisolv with hand instruments (57 microm, +/- 39) or carbide burs (32 microm, +/- 20). Even in areas with good access to the lesion, an unacceptable amount of residual caries was observed. CONCLUSION: Thus, it seems that Carisolv using rotating brushes does not reach the degree of caries removal reached by additional mechanical abrasion of Carisolv using hand instruments or conventional rotating carbide burs. |
| |