Tibial fractures following Maquet's tuberosity advancement. Apropos of 2 clinical case reports |
| |
Authors: | P Putz L Mokassa J L Janssens J Wagner |
| |
Institution: | Clinique d'orthopédie, H?pital universitaire Brugmann, Université Libre de Bruxelles, Belgique. |
| |
Abstract: | Although accustomed to using the Maquet tibial tuberosity advancement, the authors had two similar and rare complications in which a fracture of the tibial shaft occurred at the end of the vertical osteotomy. Both incidents arose from a mechanical incision effect. This can be prevented by making a larger circular hole in the distal portion of the osteotomy. |
| |