Needle biopsy of renal allografts: comparison of two techniques
Authors:Bogan, ML   Kopecky, KK   Kraft, JL   Holladay, AO   Filo, RS   Leapman, SB   Thomalla, JV
Affiliation:Department of Radiology, Indiana University School of Medicine, Indianapolis.
Abstract:Two techniques for renal allograft biopsy were retrospectively evaluated to compare relative safety and efficacy. After ultrasound (US) localization of the kidney and biopsy with a hand-held 14-gauge cutting needle, an adequate specimen was obtained in 74 of 77 cases (96%). Major complications occurred in six of these 77 cases (8%). One hundred four biopsies were performed by using a smaller 18-gauge cutting needle with a spring-loaded biopsy "gun" and real-time US guidance. With this newer technique, specimens adequate for diagnosis were obtained in 99 biopsies (95%). There was a single major complication with this technique (1%). The 18-gauge needle with real-time US guidance yields comparably adequate specimens with a lower frequency of complications.