Needle biopsy of renal allografts: comparison of two techniques |
| |
Authors: | Bogan, ML Kopecky, KK Kraft, JL Holladay, AO Filo, RS Leapman, SB Thomalla, JV |
| |
Affiliation: | Department of Radiology, Indiana University School of Medicine, Indianapolis. |
| |
Abstract: | Two techniques for renal allograft biopsy were retrospectively evaluated to compare relative safety and efficacy. After ultrasound (US) localization of the kidney and biopsy with a hand-held 14-gauge cutting needle, an adequate specimen was obtained in 74 of 77 cases (96%). Major complications occurred in six of these 77 cases (8%). One hundred four biopsies were performed by using a smaller 18-gauge cutting needle with a spring-loaded biopsy "gun" and real-time US guidance. With this newer technique, specimens adequate for diagnosis were obtained in 99 biopsies (95%). There was a single major complication with this technique (1%). The 18-gauge needle with real-time US guidance yields comparably adequate specimens with a lower frequency of complications. |
| |
Keywords: | |
|
| 点击此处可从《Radiology》浏览原始摘要信息 |
|
点击此处可从《Radiology》下载全文 |
|