首页 | 本学科首页   官方微博 | 高级检索  
     


Pediatric craniocervical spiral CT
Authors:R. A. Zimmerman  D. A. Gusnard  L. T. Bilaniuk
Affiliation:(1) Department of Radiology, The Children's Hospital of Philadelphia, Philadelphia, Pennsylvania, USA
Abstract:
Summary Spiral CT, which consists of rapid volumetric data acquisition and planar image display, was performed on 100 children undergoing examinations of the brain and head and neck for a variety of clinical indications. The technique was evaluated for image quality and impact on clinical practice. Images of the brain were generally of diagnostic quality in infants and young children but not in older children, due to their larger heads and present X-ray tube current limitations. The lower contrast resolution demands in imaging head and neck structures permitted acquisition of high quality images in all age groups. The rapidity of the technique allowed vascular phase imaging with one-sixth to one quarter the amount of contrast medium injected routinely, reduced the number of artifacts related to patient motion and occasionally permitted scanning of young patients without sedation. As a consequence, the spiral technique appears to have the potential for improving the efficiency and safety of diagnostic CT in investigation of the brain, head and neck in children.
Keywords:Spiral CT  Pediatric brain  Pediatric head and neck
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏