首页 | 本学科首页   官方微博 | 高级检索  
     


Cement-augmented anterior screw fixation of Type II odontoid fractures in elderly patients with osteoporosis
Authors:Hendrik Kohlhof  Ulrich Seidel  Sven Hoppe  Marius J. Keel  Lorin M. Benneker
Affiliation:1. Department of Orthopedic Surgery and Traumatology, Inselspital, University Hospital of Berne, 3010 Bern, Switzerland;2. Department of Orthopedic Surgery and Traumatology, University and University Hospitals of Bonn, Sigmund-Freud-Str. 25, 53127 Bonn, Germany;1. Department of Vascular Surgery, University Hospital Basel, Basel, Switzerland;2. Center for Microtherapy, Klinik Hirslanden, Zurich, Switzerland;3. Department of Vascular Surgery, Cantonal Hospital, Lucerne, Switzerland;4. Basel Institute for Clinical Epidemiology and Biostatistics, University Hospital Basel, Basel, Switzerland;1. Department of Orthopaedics and Sports Medicine, University of South Florida, Tampa, Florida;2. United States Department of Veteran Affairs, St. Petersburg, Florida;3. Department of Orthopaedics and Rehabilitation, University of Florida, Gainesville, Florida;1. Department of Orthopaedics and Traumatology, Center for Musculoskeletal Surgery, Charité-Universitätsmedizin Berlin, Berlin, Germany;2. Orthopedic Department, Hospital Märkisch Oderland, Wriezen, Germany
Abstract:
Background contextClosed reduction and internal fixation by an anterior approach is an established option for operative treatment of displaced Type II odontoid fractures. In elderly patients, however, inadequate screw purchase in osteoporotic bone can result in severe procedure-related complications.PurposeTo improve the stability of odontoid fracture screw fixation in the elderly using a new technique that includes injection of polymethylmethacrylat (PMMA) cement into the C2 body.Study designRetrospective review of hospital and outpatient records as well as radiographs of elderly patients treated in a university hospital department of orthopedic surgery.Patient sampleTwenty-four elderly patients (8 males and 16 females; mean age, 81 years; range, 62–98 years) with Type II fractures of the dens.Outcome measuresComplications, cement leakage (symptomatic/asymptomatic), operation time, loss of reduction, pseudarthrosis and revision surgery, patient complaints, return to normal activities, and signs of neurologic complications were all documented.MethodsAfter closed reduction and anterior approach to the inferior border of C2, a guide wire is advanced to the tip of the odontoid under biplanar fluoroscopic control. Before the insertion of one cannulated, self-drilling, short thread screws, a 12 gauge Yamshidi cannula is inserted from anterior and 1 to 3 mL of high-viscosity PMMA cement is injected into the anteroinferior portion of the C2 body. During polymerization of the cement, the screws are further inserted using a lag-screw compression technique. The cervical spine then is immobilized with a soft collar for 8 weeks postoperatively.ResultsAnatomical reduction of the dens was achieved in all 24 patients. Mean operative time was 64 minutes (40–90 minutes). Early loss of reduction occurred in three patients, but revision surgery was indicated in only one patient 2 days after primary surgery. One patient died within the first eight postoperative weeks, one within 3 months after surgery. In five patients, asymptomatic cement leakage was observed (into the C1–C2 joint in three patients, into the fracture in two). Conventional radiologic follow-up at 2 and 6 months confirmed anatomical healing in 16 of the19 patients with complete follow-up. In two patients, the fractures healed in slight dorsal angulation; one patient developed a asymptomatic pseudarthrosis. All patients were able to resume their pretrauma level of activity.ConclusionsCement augmentation of the screw in Type II odontoid fractures in elderly patients is technically feasible in a clinical setting with a low complication rate. This technique may improve screw purchase, especially in the osteoporotic C2 body.
Keywords:Type II odontoid fracture  Dens fracture  Screw  Cement  Augmentation
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号