Evaluation of the epidermal refractive index measured by optical coherence tomography |
| |
Authors: | M. Sand T. Gambichler G. Moussa F. G. Bechara D. Sand P. Altmeyer K. Hoffmann |
| |
Affiliation: | Department of Dermatology and Allergology, Ruhr-University Bochum, Germany. |
| |
Abstract: | BACKGROUND/AIMS: It has recently been proposed that the refractive index (RI) measured by means of optical coherence tomography (OCT) may be a valid measure for hydration of skin. In this pilot study, using OCT in vivo, we aimed to investigate the interday variability of RI measurements and acute changes of RI following the application of a moisturizer. METHODS: Twenty healthy Caucasian volunteers were investigated on their forearms using a commercially available OCT system (SkinDex 300, ISIS optronics GmbH, Mannheim, Germany) fitted with an integrated algorithm for the evaluation of the RI. The interday repeatability of the OCT method was determined performing symmetrical measurements on both forearms on day 1, 5, 9, and 13. In order to investigate the acute effect of a moisturizer on RI, OCT assessments were performed before and 10 min after the application of an aqueous lotion with a lipophilic phase. As a control, the contralateral site was investigated in the same way, except for the use of distilled water instead of the lotion. RESULTS: Assessments of interday variability revealed insignificant (P>0.05) variances between the four measurement times as expressed in very small repeatability coefficients (right arm: 0.039; left arm 0.053) and small coefficients of variance (right arm: 1.02%; left arm: 1.38%). With regard to the RIs measured over time, we could not observe significant (P>0.05) differences between the two symmetrical anatomic sites (mean+/-SD of RI: 1.3893+/-0.0142 (right arm); 1.3875+/-0.0192 (left arm)). The acute effect of the moisturizer was indicated by a significant decrease of the RI 5 min after the application of the lotion (1.399+/-0.01 vs. 1.387+/-0.02; difference between means: 0.012; P=0.033; 95% confidence interval: 0.001-0.0023). However the control site treated with distilled water did not show significant differences between the two measurement times (1.387+/-0.013 vs. 1.391+/-0.023; difference between means: -0.004; P=0.57; 95% confidence interval: -0.019-0.011). CONCLUSIONS: In this pilot study, we have demonstrated that RI evaluation via OCT is a promising technique that may be used for the assessment of skin hydration in vivo. However, the direct comparison of OCT with standard methods, ideally such as nuclear magnetic resonance spectroscopy, is necessary. |
| |
Keywords: | skin imaging high resolution interferometry measurement precision repeatability skin moisture |
|
|