应用波强技术初步评价原发性高血压患者血流动力学变化
引用本文:段凤霞,谢明星,王静,吕清,王新房,王美玲,黄君红,尹晔华.应用波强技术初步评价原发性高血压患者血流动力学变化[J].中国医学影像技术,2009,25(12):2224-2227.
作者姓名:段凤霞  谢明星  王静  吕清  王新房  王美玲  黄君红  尹晔华
作者单位:华中科技大学同济医学院附属协和医院超声影像科,湖北省分子影像重点实验室,湖北,武汉,430022
摘    要:目的 探讨波强(WI)技术评价原发性高血压患者血流动力学变化的临床应用价值.方法 对36例原发性高血压患者和30名年龄匹配的健康成人的颈动脉进行超声扫查,应用WI软件获取WI曲线,测量收缩早期峰值(W1)、收缩晚期峰值(W2)、收缩中期负向区面积(NA)、心电图R波顶点至W1的时间间隔(R-1st)、W1至W2的时间间隔(1~(st)-2~(nd))及时间标化后的R-1_(HR)~(st)、1~(st)-2~(nd)HR等参数.结果 ①与正常对照组比较,原发性高血压组W1值升高,差异有统计学意义(P<0.01),两组间W2值、NA值、R-1st、1~(st)-2~(nd)、R-1_(HR)~(st)、1~(st)-2(_(HR)~(nd))差异无统计学意义(P>0.05).②W1值与脉压、收缩压呈显著正相关(r=0.66和r=0.55,P<0.01),W2值与脉压、收缩压亦呈显著正相关(r=0.62和r=0.44,P<0.01),W1值、W2值与年龄和DBP无相关性(P>0.05).结论 WI技术提供的血流动力学参数为临床综合评价高血压患者的心脏、血管功能及其相互作用提供新方法.

关 键 词:波强  超声检查  颈动脉  高血压
收稿时间:6/3/2009 12:00:00 AM
修稿时间:2009/6/24 0:00:00

Preliminary observation of the hemodynamic changes of primary hypertension with wave intensity
DUAN Feng-xi,XIE Ming-xing,WANG Jing,LV Qing,WANG Xin-fang,WANG Mei-ling,HUANG Jun-hong and YIN Ye-hua.Preliminary observation of the hemodynamic changes of primary hypertension with wave intensity[J].Chinese Journal of Medical Imaging Technology,2009,25(12):2224-2227.
Authors:DUAN Feng-xi  XIE Ming-xing  WANG Jing  LV Qing  WANG Xin-fang  WANG Mei-ling  HUANG Jun-hong and YIN Ye-hua
Institution:Department of Ultrasound, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Hubei Key Laboratory of Molecular Imaging, Wuhan 430022, China;Department of Ultrasound, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Hubei Key Laboratory of Molecular Imaging, Wuhan 430022, China;Department of Ultrasound, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Hubei Key Laboratory of Molecular Imaging, Wuhan 430022, China;Department of Ultrasound, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Hubei Key Laboratory of Molecular Imaging, Wuhan 430022, China;Department of Ultrasound, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Hubei Key Laboratory of Molecular Imaging, Wuhan 430022, China;Department of Ultrasound, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Hubei Key Laboratory of Molecular Imaging, Wuhan 430022, China;Department of Ultrasound, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Hubei Key Laboratory of Molecular Imaging, Wuhan 430022, China;Department of Ultrasound, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Hubei Key Laboratory of Molecular Imaging, Wuhan 430022, China
Abstract:Objective To observe hemodynamic changes in patients with primary hypertension with wave intensity (WI). Methods Carotid arteries of 36 patients with primary hypertension and 30 age-matched normal controls were examined with imaging technique of WI. The following parameters were measured: the first wave peak in early ejection (W1), the second wave peak in late ejection (W2), the negative area during the mid-ejection (NA), the interval between the R wave of the ECG and the first peak of W1 (R-1st), the interval between the first peak and the second peak (1~(st)-2~(nd)), the ratio of R-1st and a cardiac cycle time R-1_(HR)~(st)) and the ratio of 1~(st)-2~(nd) , as well as one cardiac cycle time (1~(st)-2(_(HR)~(nd)). Results ①W1 in primary hypertension group increased compared with those of normal controls (P<0.01), while no significant difference of W2, NA, R-1st, 1~(st)-2~(nd), R-1_(HR)~(st), 1~(st)-2_(nd)~(HR) was detected (P>0.05). ②Both W1 and W2 correlated positively with pulse pressure (PP) and systolic blood pressure (SBP) (r=0.66, 0.55, P<0.01;r=0.62, 0.44, P<0.01). W1, W2 and age, DBP were not related significantly (P>0.05). Conclusion The hemodynamic parameters of WI technology provide a new way to evaluate the dynamics of the heart and vascular system and their interaction.
Keywords:Wave intensity  Ultrasonography  Carotid arteries  Hypertension