Shear bond strengths of plastic brackets with a mechanical base |
| |
Authors: | Liu Jia-Kuang Chang Li-Tung Chuang Shu-Fen Shieh Dar-Bin |
| |
Affiliation: | Department of Dentistry, College of Medicine, National Cheng Kung University, National Cheng Kung University Hospital, Tainan, Taiwan, ROC. jkliu@mail.ncku.edu.tw |
| |
Abstract: | This study compares the shear bond strengths of plastic brackets with a mechanical base and metal brackets using two different adhesives, and examines the modes of failure using a scanning electron microscope (SEM). Forty extracted human premolars were selected for bonding. Two types of brackets: metal and plastic-Spirit MB, and two orthodontic adhesives: System 1 + and Enlight, were used. After bonding, all samples were put into a 37 degrees C distilled water bath for 24 hours before shear bond strengths were tested. The bond strengths of the plastic brackets were significantly lower than those of the metal brackets (P < .0001). There was a statistically significant difference in bond strengths between System 1 + and Enlight for plastic brackets (P < .05), but not for metal brackets. The modes of failure predominantly occurred at the enamel/adhesive interface in the metal bracket-System 1 + group, within the adhesive in the metal bracket-Enlight and plastic bracket-System 1 + groups, and at the bracket/adhesive interface in the plastic bracket-Enlight group. |
| |
Keywords: | |
本文献已被 PubMed 等数据库收录! |
|