首页 | 本学科首页   官方微博 | 高级检索  
     


Accurate and Easy Measurement of Sliding Distance of Intramedullary Nail in Trochanteric Fracture
Authors:Nobuaki Chinzei  Takafumi Hiranaka  Takahiro Niikura  Takaaki Fujishiro  Shinya Hayashi  Noriyuki Kanzaki  Shingo Hashimoto  Yoshitada Sakai  Ryosuke Kuroda  Masahiro Kurosaka
Affiliation:Department of Orthopedic Surgery, Kobe University Graduate School of Medicine, Kobe, Japan.;*Department of Orthopedic Surgery, Takatsuki General Hospital, Takatsuki, Japan.;Division of Rehabilitation Medicine, Kobe University Graduate School of Medicine, Kobe, Japan.
Abstract:

Background

In daily clinical practice, it is essential to properly evaluate the postoperative sliding distance of various femoral head fixation devices (HFD) for trochanteric fractures. Although it is necessary to develop an accurate and reproducible method that is unaffected by inconsistent postoperative limb position on radiography, few studies have examined which method is optimal. Therefore, the purpose of this study is to prospectively compare the accuracy and reproducibility of our four original methods in the measurement of sliding distance of the HFD.

Methods

Radiographs of plastic simulated bone implanted with Japanese proximal femoral nail antirotation were taken in five limb postures: neutral, flexion, minute internal rotation, greater external rotation, and flexion with external rotation. Orthopedic surgeons performed five measurements of the sliding distance of the HFD in each of the flowing four methods: nail axis reference (NAR), modified NAR, inner edge reference, and nail tip reference. We also assessed two clinical cases by using these methods and evaluated the intraclass correlation coefficients.

Results

The measured values were consistent in the NAR method regardless of limb posture, with an even smaller error when using the modified NAR method. The standard deviation (SD) was high in the nail tip reference method and extremely low in the modified NAR method. In the two clinical cases, the SD was the lowest in the modified NAR method, similar to the results using plastic simulated bone. The intraclass correlation coefficients showed the highest value in the modified NAR method.

Conclusions

We conclude that the modified NAR method should be the most recommended based on its accuracy, reproducibility, and usefulness.
Keywords:Hip fractures   Radiography   Intramedullary nailing
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号