摘    要:
分别测量2450MHz频率下蒸馏水和不同浓度NaCl溶液的复介电常数,并对测量数据进行统计分析和修正,这对于研究利用微扰法测量高损耗生物组织的复介电常数,具有十分重要的意义。

关 键 词:微扰法  复介电常数  电导率  谐振腔
收稿时间:2003-07-14
修稿时间:2003-07-142004-04-26

Measurement and Amendment of Complex-permittivities of Distilled Water and NaCl Solution
Gao Yue,Yang Guosheng,Wang Hua,Wang Jianqi,Chen Shipei. Measurement and Amendment of Complex-permittivities of Distilled Water and NaCl Solution[J]. Journal of biomedical engineering, 2005, 22(3): 548-549
Authors:Gao Yue  Yang Guosheng  Wang Hua  Wang Jianqi  Chen Shipei
Affiliation:Faculty of Biomedical Engineering, Fourth Military Medical University, Xi'an 710033, China.
Abstract:
In this experiment, the complex-permittivities at 2 450 MHz of distilled water and various NaCl solutions were measured separately, and acquired data were analyzed and amended. The system develooped on the basis of this experiment is of great significance to studying the measurement of complex-permittivities of high-loss biologic tissues by perturbational method.
Keywords:Perturbational method Complex-permittivity Conductivity Resonant cavity