Rapid stent surface coverage after endothelial progenitor cell capture (genous) stent implantation: first optical coherence tomography report |
| |
Authors: | Cho Jin-Man Joe Byung-Hyun Kim Chong-Jin |
| |
Affiliation: | Kyunghee University, Cardiovascular Center, #149 Sangil-Dong Gangdong-Gu, Seoul, 134-727, South Korea. aceri@medimail.co.kr |
| |
Abstract: | A 78-year-old man was referred for anterior wall motion abnormality on echocardiogram. In anticipation of the urgent surgery for stomach cancer, an endothelial progenitor cell Genous capture stent (Orbus Neich Medical Technology) was implanted. After 2 weeks, optical coherence tomography was done to confirm the coverage of stent struts and all struts were fully covered by reendothelialization. The patient could undergo stomach surgery without antiplatelet therapy successfully. |
| |
Keywords: | |
本文献已被 PubMed 等数据库收录! |
|