首页 | 本学科首页   官方微博 | 高级检索  
     


Comminuted periprosthetic humeral fracture after reverse shoulder prosthesis
Authors:Renato Sommacal   Hans Rudolph Bloch   Adriana Ghidelli   Graziano Bettelli  Paolo Dalla Pria
Affiliation:(1) Department of Trauma, Hand and Reconstructive Surgery, Hospital of the J.W. Goethe-University, 60590 Frankfurt, Germany;(2) Trauma Center Murnau, Berufsgenossenschaftliche Unfallklinik, 82418 Murnau, Germany;(3) Klinik f?r Unfall-, Hand- und Wiederherstellungschirurgie, Zentrum der Chirurgie, Theodor-Stern-Kai 7, 60590 Frankfurt/Main, Germany
Abstract:Periprosthetic fractures represent a severe complication after joint replacement. A case of comminuted displaced humeral fracture around the stem of a SMR reverse shoulder prosthesis is reported. The patient was a 81-year-old lady who had had a total shoulder replacement 28 months previously. The surgical solution consisted of a partial revision of the modular implant with conservation not only of the glenoid component but also of the prosthetic humeral body, which was well fixed in the humeral metaphysis. The humeral stem was removed and a long uncemented revision stem was implanted providing fracture stabilisation and allowing early mobilisation.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏