Temperatures in and around mandibular fractures |
| |
Authors: | Kourie J Volchansky A Cleaton-Jones P E Lownie J |
| |
Affiliation: | Division of Maxillofacial and Oral Surgery, University of Witwatersrand, South Africa. |
| |
Abstract: | This study measured the temperature in and around mandibular fractures in 20 anaesthetized patients. A fine calibrated thermocouple attached to a digital thermometer was used to measure temperature at the bone surface margin of a mandibular fracture and 5 and 10 mm from the fracture; within the fracture against the bone at 5, 7 and 10 mm depths and at the base of 7 mm deep biopsy cavities 5 and 10 mm distant from the fracture line immediately after biopsy, then 1 and 2 min later. On the surface the temperature was approximately 1 degrees C warmer than at the 5 and 10 mm sites distant from the fracture. Temperature reduced at the 1 and 2 min readings after the biopsy cavity cutting. This study confirmed that the surface temperature is lower than internal bone temperatures. |
| |
Keywords: | |
本文献已被 PubMed 等数据库收录! |
|