首页 | 本学科首页   官方微博 | 高级检索  
     

诺舒阻抗控制子宫内膜切除系统治疗异常子宫出血的临床应用
引用本文:朱巍立,刘霞,毛嘉平. 诺舒阻抗控制子宫内膜切除系统治疗异常子宫出血的临床应用[J]. 浙江医学, 2015, 37(23): 1937-1939
作者姓名:朱巍立  刘霞  毛嘉平
作者单位:嘉兴市妇幼保健院妇科
摘    要:
目的 评价诺舒阻抗控制子宫内膜切除系统(下称诺舒系统)治疗异常子宫出血的可行性、安全性及有效性。 方法 收集 2011 年 6 月至 2014 年 10 月采用诺舒系统治疗的 130 例患者的临床资料,患者术后经过 1、3、6、12、24 个月门诊随访,观察其 疗效及并发症情况。 结果 130 例患者中 14.6%(19/130)为合并内科疾病引起的月经过多,其中 65 例完成 24 个月随访,95 例完成 12 个月随访,110 例完成 1~6 个月随访。手术过程均顺利,平均手术时间(包括麻醉时间)为(15.00±4.60)min,平均射频工作时间为 (80.57±4.38)s,患者术中出血<5ml。术后患者平均住院时间为(40.00±7.20)h。术后 1、3、6、12、24 个月门诊随访提示,患者整体有 效率为 100.0%(130/130);闭经率分别为 65.4%(85/130)、72.1%(88/122)、73.6%(81/110)、73.7%(70/95)、80.0%(52/65);整体治疗 满意度为 100.0%。患者术中及术后均无明显并发症。 结论 诺舒系统治疗异常子宫出血安全有效,具有临床推广意义。

关 键 词:异常子宫出血 诺舒阻抗控制子宫内膜切除系统 子宫内膜去除术

Clinical efficacy of Navosure impedance controlled endometrial ablation system in treatment of abnormal uterine bleeding
ZHU Weili,LIU Xia and MAO Jiaping. Clinical efficacy of Navosure impedance controlled endometrial ablation system in treatment of abnormal uterine bleeding[J]. Zhejiang Medical Journal, 2015, 37(23): 1937-1939
Authors:ZHU Weili  LIU Xia  MAO Jiaping
Affiliation:Jiaxing Maternity and Child Health Care Hospital
Abstract:
Objective To assess the feasibility, safety and effectiveness of Novasure impedance controlled endometrial ablation system in treatment of abnormal uterine bleeding. Methods Clinical data of 130 women with abnormal uterine bleeding treated with Novasure system from June 2011 to October 2013 were retrospectively analyzed. The clinical efficacy and complications were followed up at 1, 3, 6, 12 and 24 months after treatment. Results The procedures were completed successfully in 125 patients. The work time of the radio frequency was (80.57±4.38)s. The average time of the operation including anesthesia was (15.00±4.60) min. The blood lost was less than 5ml during the operation. The average hospitalization time after operation was (40.00±7.20)h. All the patients were followed-up for 24 months with an effective rate of 100.0% (130/130). The rate of amenorrhea was 65.4%(85/130), 72.1%(88/122), 73.6%(81/110), 73.7%(70/95), 80.0%(52/65) at 1, 3, 6, 12 and 24 months after treatment, respectively. The total degrees of satisfaction were 100.0% . No severe perioperative or postoperative complications occurred. Conclusion Novasure impedance controlled endometrial ablation system is safe and effective in treatment of abnormal uterine bleeding.
Keywords:Abnormal uterine bleeding Navosure system Endometrial ablation
点击此处可从《浙江医学》浏览原始摘要信息
点击此处可从《浙江医学》下载免费的PDF全文