首页 | 本学科首页   官方微博 | 高级检索  
     


Even short-time storage in physiological saline solution impairs endothelial vascular function of saphenous vein grafts
Authors:Manuel Wilbring  Sems Malte Tugtekin  Birgit Zatschler  Anette Ebner  Hermann Reichenspurner  Klaus Matschke  Andreas Deussen
Affiliation:aDepartment for Cardiovascular Surgery, University Heart Center, Hamburg, Germany;bDepartment for Cardiac Surgery, University Heart Center Dresden, Dresden, Germany;cInstitute for Physiology, Medical Faculty ‘Carl Gustav Carus’ Dresden, Dresden, Germany
Abstract:Objectives: A faultless endothelial layer is decisive for vascular function and therewith graft's patency. Functional impairment of the endothelium increases risk of graft thrombosis, intimal hyperplasia, and consecutive accelerated graft atherosclerosis. Storage solutions for intra-operatively harvested saphenous vein segments (SVS) might have significant impact on endothelial function. We investigated the impact of short-time storage in physiological saline solution (PSS) and a potassium-chloride- and N-acetylhistidine-enriched storage solution on venous endothelial function. Methods: Intra-operatively isolated SVSs (n = 19) were stored in different storage solutions for 90 min. They were then immediately studied in tissue bath at 36 °C with continuous oxygen insufflation. Following preconstriction with norepinephrine, dose–response relaxation curves of bradykinine (Brad) and sodium nitroprusside (SNP) were determined. We compared developed maximum wall tension, vessel constriction kinetics, endothelial cell- and smooth muscle cell (SMC)-dependent vasodilatory function. Results: Maximum vessel wall tension was reduced significantly in PSS-stored vessels (10.1 ± 9.8 mN mm−1 vs 3.5 ± 3.4 mN mm−1; p = 0.0372). Endothelium-derived vasodilatory function was likewise significantly reduced after short-time storage (20.6 ± 34.4% vs 35.0 ± 27.0%; p = 0.0437). SNP-mediated SMC-vasodilatory function was maintained equally well in both groups (88.2 ± 21.8% vs 83.0 ± 30.6% in PSS; p = n.s.). Conclusion: Even short-time storage in PSS significantly impairs endothelial vascular function. Concerning the essential role of a faultless endothelial layer, the quite common use of PSS as a storage solution for SVSs in CABG surgery has to be discussed critically.
Keywords:CABG   Vein graft   Endothelial vascular function   Preservation   Storage solution
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号