首页 | 本学科首页   官方微博 | 高级检索  
     


Assessment of magnetization transfer effects in myocardial tissue using balanced steady‐state free precession (bSSFP) cine MRI
Authors:Oliver M. Weber  Peter Speier  Klaus Scheffler  Oliver Bieri
Affiliation:1. MR Physics, Department of Medical Radiology, University of Basel and University Hospital of Basel, Basel, Switzerland;2. Siemens Switzerland AG, Healthcare Sector, Bern, Switzerland;3. Siemens AG, Healthcare Sector, Erlangen, Germany
Abstract:Magnetization transfer imaging (MTI) by means of MRI exploits the mobility of water molecules in tissue and offers an alternative contrast mechanism beyond the more commonly used mechanisms based on relaxation times. A cardiac MTI method was implemented on a commercially available 1.5 T MR imager. It is based on the acquisition of two sets of cardiac‐triggered cine balanced steady‐state free precession (bSSFP) images with different levels of RF power deposition. Reduction of RF power was achieved by lengthening the RF excitation pulses of a cine bSSFP sequence from 0.24 ms to 1.7 ms, while keeping the flip angle constant. Normal volunteers and patients with acute myocardial infarcts were imaged in short and long axis views. Normal myocardium showed an MT ratio (MTR) of 33.0 ± 3.3%. In acute myocardial infarct, MTR was reduced to 24.5 ± 9.2% (P < 0.04), most likely caused by an increase in water content due to edema. The method thus allows detection of acute myocardial infarct without the administration of contrast agents. Magn Reson Med, 2009. © 2009 Wiley‐Liss, Inc.
Keywords:magnetization transfer  balanced SSFP  cardiac MRI  myocardial infarct
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号