Image quality and radiation dose of 128-slice dual-source CT venography using low kilovoltage combined with high-pitch scanning and automatic tube current modulation
Authors:Chan Kue Park  Ki Seok Choo  Ung Bae Jeon  Seung Kug Baik  Yong Woo Kim  Tae Un Kim  Chang Won Kim  Yeon Ju Jeong  Dong Wook Jeong  Soo Jin Lim
Institution:1.Department of Radiology, Pusan National University Hospital,Pusan National University School of Medicine,Busan,Korea;2.Department of Radiology, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital,Pusan National University School of Medicine,Yangsan,Korea;3.Department of Family Medicine, Pusan National University Yangsan Hospital,Pusan National University School of Medicine,Yangsan,Korea;4.Department of Cardiology,Kim Hae Jungang Hospital,Gyeongsangnam-do,Korea
Abstract:To compare vascular enhancement, image quality, and radiation dose of 128-slice dual-source CT venography (CTV) between an imaging setting of 120 kVp with low pitch, and a setting of 100 kVp combined with high pitch and automatic tube current modulation. A total of 100 patients with suspected deep vein thrombosis and varicose veins were divided into two groups: Group 1 50 patients, 120 kVp, low pitch (0.6), and fixed 120 mA) and Group 2 (50 patients, 100 kVp, high pitch (3.0), and automatic tube current modulation]. Two radiologists, who were blinded to the image protocol, assessed vascular enhancement and image noise in the inferior vena cava (IVC), femoral vein, and popliteal vein. They also assigned an image quality score independently using a 5-point visual scale. Effective dose was estimated using the dose-length product (DLP). Group demographics, radiation dose, vascular enhancement, image noise, and image quality in the two groups were analyzed. Mean vascular enhancement of the IVC, femoral vein, and popliteal vein was significantly higher in group 2 than in group 1, and images in group 2 had significantly higher image noise. However, there were no significant differences in subjective image quality score of the IVC, femoral vein, and popliteal vein. The mean DLP in group 2 (402.10 ± 94.29 mGy cm) was significantly lower than that in group 1 (973.36 ± 63.20 mGy cm) (P < 0.001). Lower extremity CTV using 100 kVp, high pitch (3.0), and automatic tube current modulation improved vascular enhancement with acceptable image quality and low radiation dose.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号