首页 | 本学科首页   官方微博 | 高级检索  
     


Fast and accurate quantitative organic acid analysis with LC-QTOF/MS facilitates screening of patients for inborn errors of metabolism
Authors:Irene M. L. W. Körver-Keularts  Ping Wang  Huub W. A. H. Waterval  Leo A. J. Kluijtmans  Ron A. Wevers  Claus-Dieter Langhans  Camilla Scott  Daphna D. J. Habets  Jörgen Bierau
Affiliation:1.Department of Clinical Genetics,Maastricht University Medical Centre,Maastricht,The Netherlands;2.Department of Human Biology, NUTRIM School of Nutrition and Translational Research in Metabolism,Maastricht University Medical Centre,Maastricht,The Netherlands;3.Translational Metabolic Laboratory, Department of Laboratory Medicine,Radboud University Medical Center,Nijmegen,The Netherlands;4.Metabolic Laboratory, Center for Metabolic Diseases,University Children’s Hospital,Heidelberg,Germany;5.Department of Newborn Screening, Clinical Chemistry,Sheffield’s Children’s Hospital,Sheffield,UK
Abstract:
Since organic acid analysis in urine with gaschromatography-mass spectrometry (GC-MS) is a time-consuming technique, we developed a new liquid chromatography-quadrupole time-of-flight mass spectrometry (LC-QTOF/MS) method to replace the classical analysis for diagnosis of inborn errors of metabolism (IEM). Sample preparation is simple and experimental time short. Targeted mass extraction and automatic calculation of z-scores generated profiles characteristic for the IEMs in our panel consisting of 71 biomarkers for defects in amino acids, neurotransmitters, fatty acids, purine, and pyrimidine metabolism as well as other disorders. In addition, four medication-related metabolites were included in the panel. The method was validated to meet Dutch NEN-EN-ISO 15189 standards. Cross validation of 24 organic acids from 28 urine samples of the ERNDIM scheme showed superiority of the UPLC-QTOF/MS method over the GC-MS method. We applied our method to 99 patient urine samples with 32 different IEMs, and 88 control samples. All IEMs were unambiguously established/diagnosed using this new QTOF method by evaluation of the panel of 71 biomarkers. In conclusion, we present a LC-QTOF/MS method for fast and accurate quantitative organic acid analysis which facilitates screening of patients for IEMs. Extension of the panel of metabolites is easy which makes this application a promising technique in metabolic diagnostics/laboratories.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号