三种机用镍钛锉预备弯曲根管的中心定位能力比较研究
引用本文:陈幸哲,顾敏.三种机用镍钛锉预备弯曲根管的中心定位能力比较研究[J].中国实用口腔科杂志,2020,13(1):43-46.
作者姓名:陈幸哲  顾敏
作者单位:苏州大学附属第三医院 常州市第一人民医院口腔科,江苏 常州 213003
基金项目:常州市科技局应用基础研究课题(2015254);常州市卫健委青年人才科技项目(QN201708)
摘    要:目的 评价M3-Pro 2018、M3-L铂金版及ProTaper universal三种机用镍钛锉预备弯曲根管的中心定位能力。方法 收集2018年10月至2019年3月在常州市第一人民医院口腔科拔除的上颌第一磨牙,筛选出30个近中颊根管弯曲度为20 ~ 40°的近中颊根,随机分成3组,分别为M3-Pro组、M3-L组和ProTaper组,每组10个样本,分别使用M3-Pro 2018机用镍钛锉、M3-L铂金版单支锉系统及ProTaper universal机用镍钛锉预备根管。各样本在处理前后均使用CBCT扫描并利用软件mimics17.0测算距根尖5 mm范围内每毫米处的根管偏移量及轴中心率。结果 距根尖1 mm区域,M3-Pro组、M3-L组和ProTaper组的根管偏移量均值分别为0.06、0.16和0.22 mm,轴中心率均值分别为0.86、0.71和0.49,3组间差异均有统计学意义(F值分别为3.404和3.499,均P < 0.05)。距根尖3 mm区域,M3-Pro组、M3-L组和ProTaper组的根管偏移量均值分别为0.13、0.19和0.26 mm,轴中心率均值分别为0.63、0.51和0.32,3组间差异均有统计学意义(F值分别为7.567和3.996,均P < 0.05)。进一步两两比较发现,距根尖1 mm和3 mm处M3-Pro组与ProTaper组的根管偏移量及轴中心率的差异有统计学意义(P < 0.05);距根尖3 mm处M3-L组与ProTaper组的根管偏移量差异有统计学意义(P < 0.05),而两组的轴中心率差异无统计学意义(P > 0.05)。其余观测面上的根管偏移量和轴中心率在3组之间的差异均无统计学意义(均P > 0.05)。结论 M3-Pro 2018机用镍钛锉在弯曲根管的根尖区预备中能更好地顺应根管形状,减小根管偏移量,中心定位能力优于其他两种镍钛锉。

关 键 词:M3镍钛锉  根管偏移量  轴中心率  弯曲根管  中心定位能力  

Center orientation in curved root canals after the preparation by three nickel-titanium rotary instruments
CHEN Xing-zhe,GU Min.Center orientation in curved root canals after the preparation by three nickel-titanium rotary instruments[J].chinese Journal of Practical Stomatology,2020,13(1):43-46.
Authors:CHEN Xing-zhe  GU Min
Institution:(The Third Affiliated Hospital of Soochow University,The First People's Hospital of Changzhou,Changzhou 213003,China)
Abstract:Objective To evaluate the center orientation of M3-Pro 2018,M3-L and Pro Taper universal in the preparation of curved root canals. Methods Totally 30 mesial buccal roots of the first maxillary molar whose curvature was20-40°were randomly divided into three groups with 10 in each group,namely group M3-Pro,group M3-L and group Pro Taper. Three groups were prepared by M3-Pro 2018,M3-L and Pro Taper universal,respectively. CBCT and mimics17.0 software were used to calculate the canal offset and center rate of each sample in the range of 5 mm from the apex before and after preparation. Results The average canal offset of group M3-Pro,group M3-L and group Pro Taper at1 mm from apex were 0.06 mm,0.16 mm and 0.22 mm,respectively. The average center rate of group M3-Pro,group M3-L and group Pro Taper at 1 mm from apex were 0.86,0.71 and 0.49,respectively. There was significant difference among the three groups(the corresponding values of F were 3.404 and 3.499,P < 0.05). The average canal offset of group M3-Pro,group M3-L and group Pro Taper at 3 mm from apex were 0.13 mm、0.19 mm、0.26 mm,respectively. The average center rate of group M3-Pro,group M3-L and group Pro Taper at 3 mm from apex were 0.63、0.51、0.32,respectively. There was significant difference among the threegroups(the corresponding values of F were 7.567 and 3.996,P < 0.05). Further pairwise comparisons revealed that there was significant difference between group M3-Pro and group Pro Taper at 1 mm and 3 mm from apex in the aspect of canal offset and center rate(P < 0.05). There was significant difference between group M3-L and group Pro Taper at 3 mm from apex in the aspect of canal offset(P < 0.05),while there was no significant difference between these two groups concerning the center rate(P > 0.05). There was no significant difference among the 3 groups in the aspect of canal offset and center rate in other observation area except the area 1 mm and 3 mm from the apex(P > 0.05). Conclusion M3-Pro2018 complys with the canal well;it can reduce the canal offset and its ability of center orientation is better than the other two instruments in the preparation of curved canals.
Keywords:M3 instruments  canal offset  center rate  curved canal  center orientation