摘    要:
目的:建立高效液相色谱法测定替硝唑片的溶出度。方法高效液相色谱法外标法,以C18化学键和硅胶为固定相,以0.05mol/L磷酸二氢钾溶液(用磷酸调节pH值至3.5)-甲醇(80∶20)为流动相,检测波长310nm,柱温30℃,流速1.0ml/min。结果替硝唑在线性范围60~180μg /ml内与峰面积有良好的线性关系(r=0.9986)平均回收率99.28%。结论实验证明此方法简便并能准确测定替硝唑片的溶出度。

关 键 词:高效液相色谱法  甲硝唑片  溶出度

Determination of dissolution of Tinidazole Tablets by HPLC
Miao Lihong. Determination of dissolution of Tinidazole Tablets by HPLC[J]. Capital Medicine, 2014, 0(20): 91-91
Authors:Miao Lihong
Affiliation:Miao Lihong ( Beijing Institute for Drug Control of Da Xing District, Beijing (102600) China)
Abstract:
Objective To establish an HPLC method for dissolution of tinidazole tablets. Methods C18 column(4.6mm×15mm,5μm) was used with a mobile phase composed of0.05mol?l-1 potassium dihydrogen phosphate solution (Ph value adjusted to 3.5 with phosphoric acid)-methanol(80∶20) at the flow rate of 1.0 ml?min-1 .The detection wavelength was 310 nm and the temperature of the column was 30℃.Results The calibration curve of tinidazole was linear in the range of 60~180μg?ml-1(r=0.9986). The average recovery was 99.28% with an RSD of 0.3%(n=6).Conclusion This method is accurate reliable and can be used for the dissolution of tinidazole tablets.