首页 | 本学科首页   官方微博 | 高级检索  
     


Normal values for cardiovascular magnetic resonance in adults and children
Authors:Nadine Kawel-Boehm  Alicia Maceira  Emanuela R Valsangiacomo-Buechel  Jens Vogel-Claussen  Evrim B Turkbey  Rupert Williams  Sven Plein  Michael Tee  John Eng  David A Bluemke
Abstract:
Morphological and functional parameters such as chamber size and function, aortic diameters and distensibility, flow and T1 and T2* relaxation time can be assessed and quantified by cardiovascular magnetic resonance (CMR). Knowledge of normal values for quantitative CMR is crucial to interpretation of results and to distinguish normal from disease. In this review, we present normal reference values for morphological and functional CMR parameters of the cardiovascular system based on the peer-reviewed literature and current CMR techniques and sequences.

Electronic supplementary material

The online version of this article (doi:10.1186/s12968-015-0111-7) contains supplementary material, which is available to authorized users.
Keywords:Normal values   Reference values   Cardiovascular magnetic resonance