首页 | 本学科首页   官方微博 | 高级检索  
检索        

胸段食管癌三维适形放疗摆位误差研究
引用本文:洪金省,张纬建,陈金梅,蔡传书,柯春林,陈秀英,吴彬,郭飞宝.胸段食管癌三维适形放疗摆位误差研究[J].中华放射肿瘤学杂志,2004,18(1):182-185.
作者姓名:洪金省  张纬建  陈金梅  蔡传书  柯春林  陈秀英  吴彬  郭飞宝
作者单位:福建医科大学附届第一医院放疗科,福州,350005;
基金项目:福建省自然科学基金福建省卫生厅青年基金
摘    要:Objective To study the setup errors in three-dimensional conformal radiotherapy (3DCRT) for thoracic esophageal carcinoma using electronic portal imaging device(EPID) and calculate the margins from CTV to PTV. Methods Forty-one patients with thoracic esophageal carcinoma who received 3DCRT were continuously enrolled into this study. The anterior and lateral electronic portal images (EPI) were aquired by EPID once a week. The setup errors were obtained through comparing the difference between EPI and digitally reconstructed radiographs(DRR). Then the setup margins from CTV to PTV were calculat-ed. By using self paired design,22 patients received definitive radiotherapy with different margins. Group A: the margins were 10 mm in all the three axes;Group B: the margins were aquired in this study. The differ-ence were compared by Paired t-test or Wilcoxon signed-rank test. Results The margins from CTV to PTV in x,y and z axes were 8.72 mm, 10.50 mm and 5.62 mm, respectively. Between the group A and group B, the difference of the maximum dose of the spinal cord was significant(4638.7 cGy±1449.6 cGy vs. 4310.2 cGy±1528.7 cGy; t=5.48, P=0.000), and the difference of NTCP for the spinal cord was also significant (4.82%±5.99% vs. 3.64%±4.70%;Z=-2.70,P=0.007). Conclusions For patients with tho-racic esophageal carcinoma who receive 3DCRT in author's department,the margins from CTV to PTV in x, y and z axes were 8.72 mm, 10.50 mm and 5.62 mm, respectively. The spinal cord could be better protected by using these setup margins than using 10 mm in each axis.

关 键 词:食管肿瘤/放射疗法    放射疗法  三维适形    摆位误差    电子射野影像装置    

Setup error in three-dimensional conformal radiotherapy for thoracic esophageal carcinoma
HONG Jin-sheng,ZHANG Wei-jian,CHEN Jin-mei,CAI Chuan-shu,KE Chun-lin,CHEN Xiu-ying,WU Bin,GUO Fei-bao.Setup error in three-dimensional conformal radiotherapy for thoracic esophageal carcinoma[J].Chinese Journal of Radiation Oncology,2004,18(1):182-185.
Authors:HONG Jin-sheng  ZHANG Wei-jian  CHEN Jin-mei  CAI Chuan-shu  KE Chun-lin  CHEN Xiu-ying  WU Bin  GUO Fei-bao
Abstract:
Keywords:Esophageal neoplasm/radiotherapyRadiotherapy  three-dimensional conformalSetup errorElectronic portal imaging device
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号